4D Flow MRI in Ascending Aortic Aneurysms: Reproducibility of Hemodynamic Parameters

期刊

APPLIED SCIENCES-BASEL
卷 12, 期 8, 页码 -

出版社

MDPI
DOI: 10.3390/app12083912

关键词

aorta; aneurysm; hemodynamic; 4D flow MRI; reproducibility

资金

  1. Dutch Heart Foundation [CVON2017-08-RADAR]

向作者/读者索取更多资源

This study evaluated the reproducibility of 4D flow MRI-derived hemodynamic parameters in the thoracic aorta of patients with thoracic aortic aneurysm (TAA). The results showed good to excellent reproducibility for parameters such as normalized flow displacement, flow jet angle, wall shear stress, vorticity, and helicity. These parameters can be used to assess aortic aneurysms.
(1) Background: Aorta hemodynamics have been associated with aortic remodeling, but the reproducibility of its assessment has been evaluated marginally in patients with thoracic aortic aneurysm (TAA). The current study evaluated intra- and interobserver reproducibility of 4D flow MRI-derived hemodynamic parameters (normalized flow displacement, flow jet angle, wall shear stress (WSS) magnitude, axial WSS, circumferential WSS, WSS angle, vorticity, helicity, and local normalized helicity (LNH)) in TAA patients; (2) Methods: The thoracic aorta of 20 patients was semi-automatically segmented on 4D flow MRI data in 5 systolic phases by 3 different observers. Each time-dependent segmentation was manually improved and partitioned into six anatomical segments. The hemodynamic parameters were quantified per phase and segment. The coefficient of variation (COV) and intraclass correlation coefficient (ICC) were calculated; (3) Results: A total of 2400 lumen segments were analyzed. The mean aneurysm diameter was 50.8 +/- 2.7 mm. The intra- and interobserver analysis demonstrated a good reproducibility (COV = 16-30% and ICC = 0.84-0.94) for normalized flow displacement and jet angle, a very good-to-excellent reproducibility (COV = 3-26% and ICC = 0.87-1.00) for all WSS components, helicity and LNH, and an excellent reproducibility (COV = 3-10% and ICC = 0.96-1.00) for vorticity; (4) Conclusion: 4D flow MRI-derived hemodynamic parameters are reproducible within the thoracic aorta in TAA patients.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据