The increasing population and housing density have led to greater consumption of water resources, causing drinking water shortages in many regions. This article discusses the performance of a wastewater treatment system in a shopping mall in Brazil, which successfully reused water for cooling towers and toilets, resulting in significant savings in drinking water consumption.
The increasing population size and housing density are responsible for greater consumption of water resources, causing drinking water shortages in many regions. To reduce water consumption, it is essential to perform wastewater treatment, particularly in onsite non-potable water systems (ONWS). This article discusses the performance of a wastewater treatment system in a shopping mall in Brazil (City of Guarulhos, Sao Paulo State, Brazil), using data collected over 3 years (2015-2018) that resulted in water reuse ranging from 12 to 42 m(3) per day. The strategy used for this wastewater treatment and further reuse in cooling towers and toilets initially included nine steps; after adjustments, an additional step (tertiary decanter) was added. All steps were named as follows: (1) railing; (2) fats boxes; (3) aerobic reactors with selector tank; (4) denitrification; (5) flocculation; (6) secondary decanter; (7) ultrafiltration; (8) disinfection; (9) filtration by zeolites; and (10) tertiary decanter. Based on using FeCl3 as a flocculant followed by filtration by zeolites (SFM) for ion adsorption and removing above 99% of the biological oxygen demand (BOD5), generating a final BOD5 of <2.0 mg/L, total dissolved solids of 130 to 594 mg/L, pH ranging from 6.75 to 7.79, and remaining pathogen-free. This treatment demonstrated the feasibility of reusing water in air conditioning cooling towers and toilets, generating up to 797 m(3)/month of treated water for reuse with savings of up to 27% in drinking water consumption at the mall.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据