4.7 Article

A New Method for Retrieving Electron Density Profiles from the MARSIS Ionograms

期刊

REMOTE SENSING
卷 14, 期 8, 页码 -

出版社

MDPI
DOI: 10.3390/rs14081817

关键词

ionosphere; Martian ionosphere; MARSIS ionogram; ionograms inversion

资金

  1. Strategic Priority Research Program of Chinese Academy of Sciences [XDB 41000000]
  2. National Natural Science Foundation of China [42030202, 42174204, 41904140]

向作者/读者索取更多资源

This study presents a new method to invert electron density profiles of the Martian topside ionosphere from MARSIS ionograms, improving the utilization rate of the records. The method accurately captures the altitude structure and has been validated with MGS and MAVEN data. The average absolute difference in peak height is within the margin of MARSIS height resolution, and the average relative difference is only 3%.
The Martian ionosphere was actively detected by Mars Advanced Radar for Subsurface and Ionosphere Sounding (MARSIS) aboard the Mars Express. The detected echo signal of the MARSIS at an epoch is presented as a function of frequency and time delay to form an ionogram. Some MARSIS ionograms have been processed to obtain the electron density profiles of the Martian topside ionosphere. Unfortunately, more than half of the records cannot be processed with current methods due to the lack of local plasma density information at spacecraft altitude. In this work, we employ a piece-wise exponent to describe the electron density profile of the Martian topside ionosphere. The piece-wise exponent used in our method can reasonably capture the altitude structure of the Martian topside ionosphere, which has been validated with the MGS and MAVEN data. In an altitude regime of lower than 200 km, the average absolute height error of the same electron density between MGS data and fitted profiles is 0.006 km, and the average relative error is 0.008%. In an altitude regime of higher than 200 km, the average absolute height error of the same electron density between MGS data and fitted profiles is 0.55 km, and the average relative error is -0.1%. Based on the altitude structure knowledge of the Martian topside ionosphere, we put forward a new method to invert electron density profiles from MARSIS ionograms with/without local plasma density information. Compared with the previous results, the average absolute difference in the peak height of the retrieved profile is 7.38 km, within the margin of the MARSIS height resolution of 13.8 km. The average relative difference is only 3%. The application of the new method can greatly improve the utilization rate of MARSIS ionogram records.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据