4.6 Article

Bond Behavior of Concrete-Filled Steel Tube Mega Columns with Different Connectors

期刊

MATERIALS
卷 15, 期 8, 页码 -

出版社

MDPI
DOI: 10.3390/ma15082791

关键词

mega column; concrete-filled steel tube (CFST); shear studs; rib plate; push out; connectors; finite-element method

资金

  1. National Research Foundation of Korea (NRF)
  2. Korean government (MSIT) [NRF-2020R1A2C3005687, NRF-2021R1A5A1032433]

向作者/读者索取更多资源

This study investigates the bond-slip behavior between the steel tube and concrete in square CFST mega-columns through a push-out analysis. The results show that mechanical connectors significantly increase the maximum bond stress, with shear studs and rib plate connectors exhibiting the highest bond stress.
Concrete-filled steel tubes (CFSTs) are widely used in construction. To achieve composite action and take full advantage of the two materials, strain continuity at the steel-concrete interface is essential. When the concrete core and steel tube are not loaded simultaneously in regions such as beam or brace connections to the steel tubes of a CFST column, the steel-concrete bond plays a crucial role in load transfer. This study uses a validated finite-element model to investigate the bond-slip behavior between the steel tube and concrete in square CFST mega columns through a push-out analysis of eleven 1.2- x 1.2-m mega columns. The bond-slip behavior of CFST mega columns with and without mechanical connectors, including shear studs, rib plates, and connecting plates, is studied. The finite-element results indicate that the mechanical connectors substantially increased the maximum bond stress. Among the analyzed CFST mega columns, those with closely spaced shear studs and rib plate connectors with circular holes exhibited the highest bond stress, followed by plate connectors and widely spaced shear stud connectors. In the case of shear stud connectors, the stud diameter and spacing influenced the bond behavior more than the stud length. As the stud spacing decreased, the failure mode shifted from studs shearing off to outward buckling of the steel tube.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据