4.6 Article

The Mechanical Behavior of a Screwless Morse Taper Implant-Abutment Connection: An In Vitro Study

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Review Dentistry, Oral Surgery & Medicine

Survival and complications of monolithic ceramic for tooth- supported fixed dental prostheses: A systematic review and meta-analysis

Leticia Cerri Mazza et al.

Summary: This study evaluated the survival and complication rates of monolithic ceramic single crowns and fixed partial dentures, finding that monolithic ceramics showed high survival and low complication rates in tooth-supported single crowns and FPDs.

JOURNAL OF PROSTHETIC DENTISTRY (2022)

Article Engineering, Biomedical

The influence of prosthetic crown height and implant-abutment connection design selection on the long-term implant-abutment stability: A laboratory study

Aimen Bagegni et al.

Summary: The study evaluated the stability of implant-abutment connection with two internal connections at different suprastructure heights, finding that restorations with increased crown height can remain stable over an extended period, making them a reliable treatment option for increased inter-arch distance.

JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS (2021)

Article Engineering, Biomedical

Synchrotron-based micro computed tomography investigation of the implant-abutment fatigue-induced microgap changes

Aimen Bagegni et al.

Summary: This study evaluated the effect of dynamic-loading on the microgap of the internal microgap of the IAC when different supratructure heights are applied. The results showed that regardless of the crown height, the microgap between the abutment and implant systematically decreased after loading in both butt-joint and internal-conical connections.

JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS (2021)

Article Dentistry, Oral Surgery & Medicine

Clinical, radiographic and economic evaluation of short-6-mm implants and longer implants combined with osteotome sinus floor elevation in moderately atrophic maxillae: A 3-year randomized clinical trial

Jun-Yu Shi et al.

Summary: The study compared the clinical, radiographic, and economic outcomes of different lengths of implants combined with osteotome sinus floor elevation in the posterior maxilla, with 10mm implants combined with OSFE showing higher implant survival rates and lower maintenance costs.

JOURNAL OF CLINICAL PERIODONTOLOGY (2021)

Article Dentistry, Oral Surgery & Medicine

Impact of cement type and abutment height on pull-off force of zirconia reinforced lithium silicate crowns on titanium implant stock abutments: an in vitro study

Lisa Mueller et al.

Summary: The study evaluated the pull-off forces of cement-retained zirconia reinforced lithium silicate (ZLS) crowns in implant-supported single crowns on stock titanium abutments, comparing different types of cement and abutment heights. Results showed that permanent cements had the highest retention forces, while temporary cements had the lowest. Abutment height had a subordinate impact on pull-off forces.

BMC ORAL HEALTH (2021)

Article Chemistry, Physical

Mechanical Pull-Out Test of a New Hybrid Fixture-Abutment Connection: An In Vitro Study

Gianmaria D'Addazio et al.

Summary: This study tested the coupling capacity and surface modification of a new hybrid connection for implant abutment, showing a strong interface and the potential for better coupling with repeated connection activations.

MATERIALS (2021)

Article Engineering, Biomedical

In vitro assessment of connection strength and stability of internal implant-abutment connections

Michelle D. Kofron et al.

CLINICAL BIOMECHANICS (2019)

Article Dentistry, Oral Surgery & Medicine

Peri-implant tissue healing at implants with different designs and placement protocols: An experimental study in dogs

Monika Oskarsson et al.

CLINICAL ORAL IMPLANTS RESEARCH (2018)

Article Dentistry, Oral Surgery & Medicine

Effects of Axial Loading on the Pull-out Force of Conical Connection Abutments in Ankylos Implant

Pei-Fang Hsu et al.

INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS (2018)

Article Dentistry, Oral Surgery & Medicine

Peri-implantitis

Frank Schwarz et al.

JOURNAL OF PERIODONTOLOGY (2018)

Review Dentistry, Oral Surgery & Medicine

Screw retained vs. cement retained implant-supported fixed dental prosthesis

Julia-Gabriela Wittneben et al.

PERIODONTOLOGY 2000 (2017)

Article Dentistry, Oral Surgery & Medicine

Mechanical resistance of screwless morse taper and screw-retained implant-abutment connections

Cihan Sadi Ugurel et al.

CLINICAL ORAL IMPLANTS RESEARCH (2015)

Article Dentistry, Oral Surgery & Medicine

Settling of Abutments into Implants and Changes in Removal Torque in Five Different Implant-Abutment Connections. Part 1: Cyclic Loading

Ki-Seong Kim et al.

INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS (2014)

Review Engineering, Biomedical

Performance of conical abutment (Morse Taper) connection implants: A systematic review

Christian M. Schmitt et al.

JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A (2014)

Review Engineering, Biomedical

Thermal cycling for restorative materials: Does a standardized protocol exist in laboratory testing? A literature review

Anna Lucia Morresi et al.

JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS (2014)

Article Dentistry, Oral Surgery & Medicine

Survival and Complication Rates of Fixed Restorations Supported by Locking-Taper Implants: A Prospective Study with 1 to 10 Years of Follow-Up

Francesco Mangano et al.

JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY (2014)

Article Dentistry, Oral Surgery & Medicine

Effect of mechanical loading on the removal torque of different types of tapered connection abutments for dental implants

Marilene Pintinha et al.

JOURNAL OF PROSTHETIC DENTISTRY (2013)

Article Dentistry, Oral Surgery & Medicine

The Effect of Crown/Implant Ratio and Crown Height Space on Stress Distribution in Unsplinted Implant Supporting Restorations

Joseph Nissan et al.

JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY (2011)

Article Dentistry, Oral Surgery & Medicine

The Effect of Splinting Implant-Supported Restorations on Stress Distribution of Different Crown-Implant Ratios and Crown Height Spaces

Joseph Nissan et al.

JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY (2011)

Article Dentistry, Oral Surgery & Medicine

In Vitro Evaluation of the Removal Force of Abutments in Frictional Dental Implants

Joao Cesar Zielak et al.

JOURNAL OF ORAL IMPLANTOLOGY (2011)

Article Dentistry, Oral Surgery & Medicine

Effect of repeated torque/mechanical loading cycles on two different abutment types in implants with internal tapered connections: an in vitro study

Abilio Ricciardi Coppede et al.

CLINICAL ORAL IMPLANTS RESEARCH (2009)

Article Dentistry, Oral Surgery & Medicine

A systematic review of the performance of ceramic and metal implant abutments supporting fixed implant reconstructions

Irena Sailer et al.

CLINICAL ORAL IMPLANTS RESEARCH (2009)

Article Dentistry, Oral Surgery & Medicine

In vitro evaluation of a mechanical testing chewing simulator

Martin Steiner et al.

DENTAL MATERIALS (2009)

Article Dentistry, Oral Surgery & Medicine

A systematic review of the 5-year survival and complication rates of implant-supported single crowns

Ronald E. Jung et al.

CLINICAL ORAL IMPLANTS RESEARCH (2008)

Editorial Material Dentistry, Oral Surgery & Medicine

Peri-implant diseases: Consensus Report of the Sixth European Workshop on Periodontology

Jan Lindhe et al.

JOURNAL OF CLINICAL PERIODONTOLOGY (2008)

Article Dentistry, Oral Surgery & Medicine

Fatigue resistance of two implant/abutment joint designs

A Khraisat et al.

JOURNAL OF PROSTHETIC DENTISTRY (2002)

Article Dentistry, Oral Surgery & Medicine

Clinical evaluation and prosthetic complications of single tooth replacements by non-submerged implants

R Mericske-Stern et al.

CLINICAL ORAL IMPLANTS RESEARCH (2001)