4.0 Article

The use of SNAP and T1-weighted VISTA in cervical artery dissection

期刊

INTERVENTIONAL NEURORADIOLOGY
卷 29, 期 3, 页码 235-242

出版社

SAGE PUBLICATIONS INC
DOI: 10.1177/15910199221082847

关键词

Cervical artery dissection; simultaneous noncontrast angiography and intraplaque hemorrhage; volumetric isotropic turbo spin echo acquisition; intramural hematoma

向作者/读者索取更多资源

This study compared the abilities of vessel wall magnetic resonance imaging techniques, SNAP sequence and T1-weighted volumetric isotropic turbo spin echo acquisition (T1-w VISTA) sequence, in evaluating cervical artery dissection (CAD). The results showed that both SNAP and T1-w VISTA sequences had the same diagnostic performance in CAD diagnosis, and their consistencies with the final diagnosis were good. Additionally, SNAP showed better intramural hematoma (IMH)-wall contrast than T1-w VISTA.
Background and Purpose Some cervical artery dissection (CAD) can't be easily confirmed by commonly used angiography techniques in clinical practice. We aimed to compare the abilities of the vessel wall magnetic resonance imaging (MRI) techniques including simultaneous noncontrast angiography and intraplaque hemorrhage (SNAP) sequence and T1-weighted volumetric isotropic turbo spin echo acquisition (T1-w VISTA) sequence alone for evaluating CAD. Materials and Methods From July 2017 to October 2020, 59 patients underwent MRI examinations including SNAP and T1-w VISTA sequences for cervical artery pathologies. SNAP and T1-w VISTA images were retrospectively and independently reviewed to evaluate their diagnostic performances of CAD by using the final diagnosis as the reference standard which was established by clinical history, physical examination, and all available images. The agreement between T1-w VISTA and SNAP in the identification of the imaging features of CAD, including intramural hematoma (IMH), intimal flap, and double lumen, were compared. The IMH-wall contrasts by T1-w VISTA and SNAP were also compared. Results CAD was confirmed in 43 of the 59 patients. T1-w VISTA and SNAP showed the same diagnostic performance, and their consistencies with the final diagnosis were good (kappa = 0.776, p < 0.001). The sensitivity and specificity in CAD diagnosis were 0.978 and 0.750 for T1-w VISTA and SNAP. The IMH, intimal flap, and double lumen observed on SNAP were also determined by T1-w VISTA (kappa = 1.000, p < 0.001 for all). The SNAP sequence showed higher IMH-wall contrast than T1-w VISTA (7.34 +/- 4.56 vs. 3.12 +/- 1.17, p < 0.001). Conclusions SNAP and T1-w VISTA sequences had the same performance in CAD diagnosis, thus they were both recommended. In addition, SNAP showed better IMH-wall contrast than T1-w VISTA.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.0
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据