4.4 Article

Agreement Among Multiple Observers on Crystal Identification by Synovial Fluid Microscopy

期刊

ARTHRITIS CARE & RESEARCH
卷 75, 期 3, 页码 682-688

出版社

WILEY
DOI: 10.1002/acr.24874

关键词

-

向作者/读者索取更多资源

This study evaluated the agreement among multiple observers in crystal identification using compensated polarized microscopy. The results showed that the method remained consistent in detecting and identifying crystals in synovial fluid, confirming its high utility for clinical practice.
Objective. Despite the fact that polarized microscopy remains the gold standard for diagnosing crystal arthritis, some uncertainties hamper full implementation in clinical practice. We undertook this study to analyze the agreement among multiple observers in crystal identification using compensated polarized microscopy, as well as to assess potential outcome modifiers. Methods. This was a cross-sectional, observational study with consecutive synovial fluid sampling. Samples were immediately analyzed when possible or kept refrigerated at 4 degrees C. Five observers analyzed them separately, blinded to clinical data, using a compensated polarized optical microscope (400x), through 3 stages (ordinary, simple polarized, and compensated polarized light) to detect and identify crystals. They recorded the presence and type of crystal (no crystals, monosodium urate [MSU], and calcium pyrophosphate dihydrate [CPP]). Interrater agreement was measured by Cohen's kappa. Subanalyses were performed on visualization delay and cumulative expertise. Discrepancies between each stage of the microscopy and the final decision were also examined. Results. A total of 250 observations from 50 samples completed full assessment. Overall, kappa = 0.74 (95% confidence interval [95% CI] 0.64-0.84), indicating good agreement. Agreement for crystal detection was kappa = 0.71 (95% CI 0.59-0.82), for MSU was kappa = 0.88 (95% CI 0.75-1.0), and for CPP was kappa = 0.69 (95% CI 0.56-0.82). Most of the crystal identifications were already made by ordinary light. No differences between observations made before or after 24 hours (P = 0.859) or in expertise on crystal analysis (P = 0.989) were found. Observations performed under ordinary light matched the final diagnosis in 96.8% of cases (242 of 250). Conclusion. Compensated polarized microscopy remained consistent in detecting and identifying crystals in synovial fluid, even when examined among multiple observers, confirming its high utility for clinical practice.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据