4.4 Article

Quantitative nanoscale imaging using transmission He ion channelling contrast: Proof-of-concept and application to study isolated crystalline defects

期刊

ULTRAMICROSCOPY
卷 233, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.ultramic.2021.113439

关键词

-

资金

  1. Luxembourg National Research Fund (FNR) [PRIDE17/12246511/PACE, C16/MS/11354626]
  2. European Union's Horizon 2020 Research and Innovation Programme [720964]

向作者/读者索取更多资源

The newly developed microscope prototype npSCOPE was utilized to conduct Scanning Transmission Ion Microscopy (STIM) using keV He+ ions, revealing rich microstructural features including isolated nanoscale twin bands in a 50 nm thick gold membrane. The experimental conditions showed a lateral resolution close to 30 nm in STIM imaging. Monte Carlo simulations were performed to derive insights related to beam broadening and its effect on transmission image resolution, while observations indicated the sensitivity of channelling contrast to even small changes in illumination conditions.
A newly developed microscope prototype, namely npSCOPE, consisting of a Gas Field Ion Source (GFIS) column and a position sensitive Delay-line Detector (DLD) was used to perform Scanning Transmission Ion Microscopy (STIM) using keV He+ ions. One experiment used 25 keV ions and a second experiment used 30 keV ions. STIM imaging of a 50 nm thick free-standing gold membrane exhibited excellent contrast due to ion channelling and revealed rich microstructural features including isolated nanoscale twin bands which matched well with the contrast in the conventional ion-induced Secondary Electron (SE) imaging mode. Transmission Kikuchi Diffraction (TKD) and Backscattered Electron (BSE) imaging were performed on the same areas to correlate and confirm the microstructural features observed in STIM. Monte Carlo simulations of the ion and electron trajectories were performed with parameters similar to the experimental conditions to derive insights related to beam broadening and its effect in the degradation of transmission image resolution. For the experimental conditions used, STIM imaging showed a lateral resolution close to30 nm. Dark twin bands in bright grains as well as bright twin bands in dark grains were observed in STIM. Some of the twin bands were invisible in STIM. For the specific experimental conditions used, the ion transmission efficiency across a particular twin band was found to decrease by a factor of 2.8. Surprisingly, some grains showed contrast reversal when the Field of View (FOV) was changed indicating the sensitivity of the channelling contrast to even small changes in illumination conditions. These observations are discussed using ion channelling conditions and crystallographic orientations of the grains and twin bands. This study demonstrates for the first time the potential of STIM imaging using keV He+ ions to quantitatively investigate channelling in nanoscale structures including isolated crystalline defects.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据