4.7 Article

Investigating the reliability of electrically conductive adhesives for shingled photovoltaic Si modules

期刊

出版社

ELSEVIER
DOI: 10.1016/j.solmat.2021.111403

关键词

ECA; Shingled PV Module; Stability; Acceleration test; Ag diffusion

资金

  1. New & Renewable Energy of the Korea Institute of Energy Technology Evaluation and Planning (KETEP)
  2. Ministry of Trade, Industry & Energy, Republic of Korea [20183010014270, 20193010014530, 20203030010300]
  3. Korea Evaluation Institute of Industrial Technology (KEIT) [20183010014270, 20193010014530, 20203030010300] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

向作者/读者索取更多资源

This study investigates the environmental stability of an electrically conductive adhesive (ECA) used in shingled photovoltaic (PV) modules. The results show that the electrical properties of the ECA did not deteriorate under hot and humid conditions, but the performance of the shingled modules degraded due to current leakage causing a drop in the fill factor (FF). Physicochemical analysis revealed that silver atoms diffused from the ECA joint to the silicon wafer, acting as a shunt path for the solar cell.
This paper discusses the environmental stability of an electrically conductive adhesive (ECA) applied to shingled photovoltaic (PV) modules. This study aims to verify the degradation behavior of ECA joints when shingled PV modules are exposed to an accelerated aging test under hot and humid environmental conditions. To achieve this, we prepared shingled PV modules through an assembly process wherein five pre-cut crystalline silicon solar cells were bonded with a ECA paste cured by an infrared lamp, and then stored under damp heat (85 degrees C/85% RH) and high temperature (65 and 85 degrees C) conditions. To confirm the aging of the ECA, we determined the changes in the electrical resistance of the ECA and in the efficiencies of the shingled PV modules. Results suggest that the electrical properties of the ECA did not deteriorate under heat and moisture conditions, while the performance of the shingled modules degraded under the same conditions. It was confirmed that the degradation in performance was mainly due to a drop in the fill factor (FF) caused by current leakage. Physicochemical analyses of the samples revealed that Ag atoms, which diffused from the ECA joint to the Si wafer, acted as the shunt path for the solar cell. The bonding properties of the ECA joint to moisture were evaluated as well.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据