4.7 Article

A dual-channel luminescent signal readout nanoprobe for rapid monitoring of biogenic amines in milk and yogurt

期刊

SENSORS AND ACTUATORS B-CHEMICAL
卷 357, 期 -, 页码 -

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2022.131435

关键词

Fluorescence; Biogenic amines; Ratiometric sensor; Carbon dots

资金

  1. National Natural Science Foundation of China [22001193, 22127803, 22174110]
  2. Industrial Support Plan of Gansu Provincial Department of Education [2021cyzc-01]
  3. Special Fund Project for Guiding Local Scientific and Technological Development by the Central Government [2020-2060503-17]
  4. Program for Chang Jiang Scholars and Innovative Research Team, Ministry of Education, China [IRT-16R61]
  5. Program of Innovation and Entrepreneurial for Talent, Lanzhou, Gansu Province, China [2014-RC-39]

向作者/读者索取更多资源

In this study, a dual-channel luminescent signal readout nanoprobe o-CDs@methyl red was used for rapid, sensitive, and visual detection of biogenic amines. The method showed high sensitivity and fast response, and was successfully applied to real food samples.
As biologically active small molecular, biogenic amines (BAs) could be served as an important index of food spoilage and contamination. In addition, excessive intake of biogenic amines usually can cause a serious impact on human health. Therefore, it is of great significance to establish a reliable, sensitive, and non-invasive method for the detection of biogenic amines in foods. To address the above problems, optical sensing method utilizing dual-channel fluorescence outputs could be considered as a powerful technique, which can achieve high accuracy and even visual detection. Herein, we have demonstrated for the first time the use of a dual-channel luminescent signal readout nanoprobe o-CDs@methyl red (CDs stands for carbon dots) for rapid, sensitive, and visual detection of biogenic amines. Such probe was prepared by covalently modifying methyl red on NH2-rich carbon dots, in which o-CDs served as a reference signal and methyl red acted as a signal report unit for BAs. Upon the addition of BAs, the fluorescence intensity of methyl red increases, while that of o-CDs remains almost unchanged. It was found that such fluorescence platform can detect tyramine with high sensitivity (LOD: 0.01 mu M) and fast response (30 s). More importantly, the proposed method can be successfully applied for biogenic amines detection in real milk and yogurt samples, indicating that the as-prepared probe holds the further potential for practical application in control and monitoring of food quality and freshness.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据