4.7 Article

Long term stability of cantilever gas nanosensors to detect Euschistus heros (F.) pheromone release by rubber septa

期刊

SENSORS AND ACTUATORS B-CHEMICAL
卷 359, 期 -, 页码 -

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2022.131566

关键词

Rubber septa; Pheromone; Gas nanosensor; Stability

资金

  1. National Council for Scientific and Technological Development - Brazil (CNPq)
  2. Coordination for the Improvement of Higher Education Personnel-Brazil (CAPES) [001]
  3. Research Support Foundation of State of Rio Grande of Sul - Brazil (FAPERGS)
  4. Financiadora de Estudos e Projetos (Finep)
  5. Embrapa Biotechnology (Brasilia)

向作者/读者索取更多资源

This study presents the use of cantilever gas nanosensors coated with PANI/PSS and PANI.Ag to monitor the release of neotropical brown stink bug pheromone in rubber septa. The results show a daily reduction in resonance frequency of the nanosensors when exposed to the pheromone-containing rubber septum. Relative humidity does not affect the resonance frequency of the nanosensors. After 365 days of evaluation, the nanosensors exhibit a long-term stable response and can successfully detect the release of pheromone molecules.
This work presents the use of cantilever gas nanosensors coated with PANI/PSS and PANI.Ag to monitor the release of neotropical brown stink bug, Euschistus heros (F.) pheromone in rubber septa (insect pheromone dispenser). The rubber septa was impregnated with the 2,6,10-methyl trimethyltridecanoate compound, the main component of the sexual pheromone of E. heros stink bug. Studies were conducted to detect and determine the pheromone release ratio under laboratory conditions during two months. Both cantilever nanosensors showed a daily reduction in resonance frequency when exposed to the rubber septum containing the pheromone, which was not observed in the control cantilever. The relative humidity did not presented influence on the nanosensors resonance frequency. The stability of the cantilever nanosensors was evaluated for 365 days (twelve months). Was observed a slight reduction of 1.4% in the resonance frequency for the nanosensor of PANI/PSS after 300 days of storage, and of 0.32% for the nanosensor PANI.Ag after 360 days. In this way, the gas nano sensors can be stored for long time presenting a long-term stable response and used successfully to detect the release of pheromone molecules.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据