4.7 Article

Evaluating perfluorooctanoic acid (PFOA) and perfluorooctanesulfonic acid (PFOS) removal across granular activated carbon (GAC) filter-adsorbers in drinking water treatment plants

期刊

SCIENCE OF THE TOTAL ENVIRONMENT
卷 838, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.scitotenv.2022.156406

关键词

Granular activated carbon; PFOA; PFOS; Adsorption; Biodegradation

资金

  1. Natural Sciences and Engineering Research Council of Canada (NSERC) [IRCPJ 428979-16]

向作者/读者索取更多资源

This study evaluated the removal of perfluorooctanic acid (PFOA) and perfluorooctanesulfonic acid (PFOS) using granular activated carbon (GAC) harvested from filter-adsorbers in drinking water treatment plants. The results showed that GAC can achieve significant removal of PFOA and PFOS through adsorption. Factors such as GAC service time and empty bed contact time (EBCT) were found to affect the removal efficiency. An empirical model was proposed to predict the removal of PFOA and PFOS based on GAC service time and EBCT.
Granular activated carbon (GAC) was harvested from six filter-adsorbers that are used for taste and odour control in three drinking water treatment plants in Ontario, Canada, and evaluated for the removal of perfluorooctanic acid (PFOA) and perfluorooctanesulfonic acid (PFOS) using minicolumn tests under different operational conditions. Parallel column tests were conducted using unsterilized GAC and sterilized GAC to distinguish adsorption from potential biodegradation of PFOA and PFOS across the GAC. It was observed that the GAC could achieve approximately 20% to 55% of PFOA and PFOS removal even after a long period of GAC operation (e.g., 6 years). There was no evidence of PFOA and PFOS biodegradation, so the removal in GAC can be attributed solely to adsorption under the conditions tested. However, in one location, there was evidence suggesting both removal and formation of PFOS and PFOA across the GAC, with the formation presumably due to the biotransformation of pre-existing precursors in the source water. Additionally, GAC service time and empty bed contact time (EBCT) were identified to be important factors that could affect the removal of PFOA and PFOS. Based on this information, an empirical model was proposed to predict PFOA and PFOS removal in GAC filter-adsorbers as a function of GAC service time and EBCT. This study provides useful information for utilities that have installed GAC for taste and odour control but may consider per-and polyfluoroalkyl substances (PFAS) removal as an additional voluntary objective or due to more stringent guidelines.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据