4.7 Article

Split-range control for improved operation of solar absorption cooling plants

期刊

RENEWABLE ENERGY
卷 192, 期 -, 页码 361-372

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.renene.2022.04.064

关键词

Renewable energy; Fresnel solar collector; Defocus; Absorption chiller; Solar cooling; Split-range control

资金

  1. Coordenacao de Aperfeicoamento de Pessoal de Nivel Superior (CAPES) [001]
  2. Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq) [304032/2019-0]
  3. Agencia Estatal de Investigacion (AEI) of the Spanish Ministry of Science and Innovation [PID2019-104149RB-I00/10.13039/501100011033]
  4. European Research Council under Advanced Research Grant OCONTSOLAR [789051]
  5. IFRS-campus Rio Grande for capacity support
  6. European Research Council (ERC) [789051] Funding Source: European Research Council (ERC)

向作者/读者索取更多资源

This paper proposes the first application of a split-range control technique on a concentrating solar collector to improve the production of an absorption plant. Control techniques are simulated and compared in an absorption plant in Spain. The results demonstrate that the proposed controllers significantly reduce the effort of control actuators and improve energy and exergy production.
This paper proposes the first application of a split-range control technique on a concentrating solar collector to improve an absorption plant production. Solar absorption plants have solar power availability in phase with cooling demand under design conditions. Thus, it is a powerful cooling technology in the context of renewable energy and energy efficiency. These plants need control systems to cope with solar irradiance intermittency, reject irradiation disturbances, manage fossil fuels backup systems and dump closed-loop thermal-hydraulic oscillations. In this work, control techniques are proposed and simulated in an absorption plant in Spain. The plant consists of a concentrating Fresnel solar collector connected to an absorption chiller. The objectives are to operate with 100% renewable solar energy and avoid safety defocus events while reducing temperature oscillations and control actuators effort. Firstly, the current available plant controllers are defined, then two modifications are proposed. The first modification is a split-range controller capable of manipulating both flow and defocus of the Fresnel collector, the second modification is a PI controller to substitute the original chiller on-off controller. The results compare, through validated models, the different control systems and indicate that using both proposed controllers reduces 94% of the sum of actuators effort and 43% of the integral of absolute set-point tracking error compared to the plant's factory pre-set controllers. The suggested controllers increase 66% of energy production and 63% of exergy production. Besides, the split-range technique can be extended to any concentrating solar collector control. (c) 2022 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).