4.7 Article

On-Scalp Optically Pumped Magnetometers versus Cryogenic Magnetoencephalography for Diagnostic Evaluation of Epilepsy in School-aged Children

期刊

RADIOLOGY
卷 304, 期 2, 页码 429-434

出版社

RADIOLOGICAL SOC NORTH AMERICA (RSNA)
DOI: 10.1148/radiol.212453

关键词

-

向作者/读者索取更多资源

This study compared the effectiveness of cryogenic and on-scalp MEG in detecting and localizing focal interictal epileptiform discharges (IEDs) in children with epilepsy. The results showed that on-scalp MEG had higher IED amplitudes and signal-to-noise ratios compared to cryogenic MEG, and the localization value was similar between the two modalities.
Background: Magnetoencephalography (MEG) is an established method used to detect and localize focal interictal epileptiform discharges (IEDs). Current MEG systems house hundreds of cryogenic sensors in a rigid, one-size-fits-all helmet, which results in several limitations, particularly in children. Purpose: To determine if on-scalp MEG based on optically pumped magnetometers (OPMs) alleviates the main limitations of cryogenic MEG. Materials and Methods: In this prospective single-center study conducted in a tertiary university teaching hospital, participants underwent cryogenic (102 magnetometers, 204 planar gradiometers) and on-scalp (32 OPMs) MEG. The two modalities for the detection and localization of IEDs were compared. The t test was used to compare IED amplitude and signal-to-noise ratio (SNR). Distributed source modeling was performed on OPM-based and cryogenic MEG data. Results: Five children (median age, 9.4 years [range, 5-11 years]; four girls) with self-limited idiopathic (n = 3) or refractory (n = 2) focal epilepsy were included. IEDs were identified in all five children with comparable sensor topographies for both MEG devices. IED amplitudes were 2.3 (7.2 of 3.1) to 4.6 (3.2 of 0.7) times higher (P<.001) with on-scalp MEG, and the SNR was 27% (16.7 of 13.2) to 60% (12.8 of 8.0) higher (P value range:.001-.009) with on-scalp MEG in all but one participant (P =.93), whose head movements created pronounced motion artifacts. The neural source of averaged IEDs was located at approximately 5 mm (n = 3) or higher (8.3 mm, n = 1; 15.6 mm, n = 1) between on-scalp and cryogenic MEG. Conclusion: Despite the limited number of sensors and scalp coverage, on-scalp magnetoencephalography (MEG) based on optically pumped magnetometers helped detect interictal epileptiform discharges in school-aged children with epilepsy with a higher amplitude, higher signal-to-noise ratio, and similar localization value compared with conventional cryogenic MEG. (C) RSNA, 2022

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据