4.7 Article

Arsenic adsorption by low-cost laterite column: Long-term experiments and dynamic column modeling

期刊

PROCESS SAFETY AND ENVIRONMENTAL PROTECTION
卷 160, 期 -, 页码 868-875

出版社

ELSEVIER
DOI: 10.1016/j.psep.2022.03.010

关键词

Arsenic removal; Adsorption column; Household filter; Laterite; Linear driving force approximation model

资金

  1. Aus4Innovation program - a development cooperation initiative - ustralian Department of Foreign Affairs and Trade and InnovationXchange [A4I077UTS]
  2. University of Technology Sydney

向作者/读者索取更多资源

In this study, a natural laterite adsorbent from Vietnam was investigated for its potential application in removing arsenic contamination from drinking water supplies. The adsorbent exhibited good adsorption capacity for arsenic and the study also developed a model to predict the adsorption performance in column experiments and filters.
Arsenic (As) contamination of drinking water supplies is a major concern in many countries due to its large concentration in groundwater and high toxicity. In this study, batch adsorption experiments on a natural laterite adsorbent from Vietnam (NLTT) were firstly conducted, followed by four column adsorption ex-periments using NLTT working with synthetic water under different experimental conditions (initial ar-senate As(V) concentration: 0.1 and 0.5 mg/L; bed height: 0.15 and 0.41 m). Results from the batch equilibrium adsorption study show that all three models -Sips, Langmuir, and Freundlich -fitted the ex-perimental data very well. The Sips and Langmuir maximum adsorption capacities were 0.76 mg/g and 0.58 mg/g, respectively. At an As(V) concentration of 0.5 mg/L, adsorption breakthrough occurred at 28 h and 122 h for column heights of 0.15 m and 0.41 m, respectively. When As(V) concentration fell to 0.1 mg/L, the breakthrough times rose to 144 h and 240 h, respectively. A linear driving force approximation (LDFA) model incorporating the Sips equation was calibrated with data from the equilibrium and kinetic adsorption experiments and one column adsorption experiment (initial concentration: 0.1 mg/L; bed height: 0.15 m). The LDFA model with the calibrated model coefficients could predict the breakthrough curves and ad-sorption time in the three other column experiments and four household column filters used to treat As contaminated groundwater in Vietnam. The study revealed that application potential for NLTT in column adsorption studies and field trials to remove As(V) is significant despite this study having limited data. Subsequently, refining the model based on simulation of results is cost-effective, saves time and effort, and negates the need for multiple experiments to optimize filter conditions.(c) 2022 Institution of Chemical Engineers. Published by Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据