4.6 Article

Optimization of adaptive filter control parameters for non-invasive fetal electrocardiogram extraction

期刊

PLOS ONE
卷 17, 期 4, 页码 -

出版社

PUBLIC LIBRARY SCIENCE
DOI: 10.1371/journal.pone.0266807

关键词

-

资金

  1. European Regional Development Fund in the Research Centre of Advanced Mechatronic Systems project through the Operational Programme Research, Development and Education [CZ.02.1.01/0.0/0.0/16_019/0000867]
  2. Ministry of Education of the Czech Republic [SP2021/32, SP2022/34]

向作者/读者索取更多资源

This paper presents a novel method for optimizing the control parameters of hybrid systems used for non-invasive fetal electrocardiogram (fECG) extraction. By testing and optimizing different adaptive algorithms, the study found improved results in fetal heart rate monitoring and detection of fetal hypoxia. The approach has the potential to be used in clinical practice for extracting high-quality fetal ECG signals and offering new possibilities for non-invasive fetal electrocardiography diagnostics.
This paper is focused on the design, implementation and verification of a novel method for the optimization of the control parameters of different hybrid systems used for non-invasive fetal electrocardiogram (fECG) extraction. The tested hybrid systems consist of two different blocks, first for maternal component estimation and second, so-called adaptive block, for maternal component suppression by means of an adaptive algorithm (AA). Herein, we tested and optimized four different AAs: Adaptive Linear Neuron (ADALINE), Standard Least Mean Squares (LMS), Sign-Error LMS, Standard Recursive Least Squares (RLS), and Fast Transversal Filter (FTF). The main criterion for optimal parameter selection was the F1 parameter. We conducted experiments using real signals from publicly available databases and those acquired by our own measurements. Our optimization method enabled us to find the corresponding optimal settings for individual adaptive block of all tested hybrid systems which improves achieved results. These improvements in turn could lead to a more accurate fetal heart rate monitoring and detection of fetal hypoxia. Consequently, our approach could offer the potential to be used in clinical practice to find optimal adaptive filter settings for extracting high quality fetal ECG signals for further processing and analysis, opening new diagnostic possibilities of non-invasive fetal electrocardiography.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据