This study investigates the prospects of using emissions from a microplasma source to measure the C-13/C-12 isotope ratio in CO2. The study reveals that the visible emission spectrum can be used to quantify the abundance of C-12 and C-13 in the sample, but further improvements in precision and accuracy are needed for most scientific applications.
This study investigates the prospects of using emissions from the discharge of a stripline split-ring resonator microplasma source to measure the C-13/C-12 isotope ratio in CO2. The plasma source was used in a measurement scheme called microplasma emission spectroscopy, in which the visible emission spectrum of the CO2 discharge was investigated using a Charge- Coupled Device (CCD) spectrometer. The study revealed that the major isotope dependencies of the spectrum originated from the Angstrom system (B-1 Sigma(+) -> A(1)Pi) of CO molecules that had been converted from CO2 in the discharge. Although at least four of the bands of the Angstrom system showed clear isotopic dependences, the (0-3) band at 561 nm was concluded to show the most prospects for spectrometric applications because of a combination of wide isotopic shift and low background. A theoretical model of this band was constructed and used in a partial least squares fitting algorithm, to quantify the abundance of C-12 and C-13 in the sample. This signal processing method was shown to be robust and linear over the whole dynamic range of C-13/C-12 ratios (1%-100%) but required a ten-fold improvement in precision and accuracy at naturally occurring C-13 levels (1.07%-1.12%) to be useful in most scientific applications. However, several promising ways of achieving such an improvement have been presented, and the results demonstrate the potential of creating a simple, cost-effective, and highly miniaturized system for isotope ratio measurements, which could offer great advantages to scientists in many different fields, from environmental science to planetary exploration.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据