4.7 Article

Thermal effects on SARS-CoV-2 transmission in peristaltic blood flow: Mathematical modeling

期刊

PHYSICS OF FLUIDS
卷 34, 期 6, 页码 -

出版社

AIP Publishing
DOI: 10.1063/5.0095286

关键词

-

向作者/读者索取更多资源

This study investigates the impact of temperature on virus transmission in blood vessels and predicts the transmission process from infected individuals to non-infected individuals. The findings show that microdroplets carry a smaller amount of virus particles, indicating airborne transmission is less harmful. Additionally, the study reveals the rapid propagation of the SARS-CoV-2 virus in the circulatory system and estimates the infection in blood and tissues.
SARS-CoV-2 is a novel viral species that has been identified as a highly infectious disease. Scientists have endeavored to collect essential information to better characterize the behavior of this virus, including droplet transmission and airborne effects. However, it is not clear, thus far, whether temperature can substantially alter the pandemic trajectory. This present study, therefore, aims to investigate how temperature may affect virus transmission in peristaltic blood vessels and, furthermore, how virus density and particle diameter will affect the transmission of the virus from an infected person to a non-infected person. The modeling deployed assumes that coronavirus particles with a diameter of 120 mu m and a density of 1 g/cm(3) move in the direction of blood flow. The quantity of SARS-CoV-2 virions (entire virus particles) inside a microdroplet is calculated by considering the Kepler conjecture method, and the transmission percentage of the viral load is also computed. It is observed that the microdroplet carries a smaller amount of coronavirus particles, so an airborne ( D-P < 2 mu m ) infection is less harmful. Furthermore, computational simulations using the proposed model reveal some interesting insight into how rapidly the SARS-CoV-2 virus propagates in the circulatory system, and estimate the infection in blood and tissues. From these results, it is found that the small virion (d(p) < 100 nm) rapidly settles inside the bloodstream and infects tissues; however, the duration of infection is short due to the low viscosity of the blood. Furthermore, the closed packed structure of the virions is loosened in the blood vessel due to the temperature of the blood. Published under an exclusive license by AIP Publishing.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据