Characterization of the PTB ultra-high pulse dose rate reference electron beam

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Article Engineering, Biomedical

Response of diamond detectors in ultra-high dose-per-pulse electron beams for dosimetry at FLASH radiotherapy

R. Kranzer et al.

Summary: This study investigates the response of microDiamond detectors and their prototypes in ultra-high DPP electron beams. It is found that commercially available microDiamond detectors have limitations in terms of linearity at ultra-high DPP, but this is not an intrinsic limitation of the detector principle. By reducing sensitivity and using low series resistance, the linear range of the detectors can be extended.

PHYSICS IN MEDICINE AND BIOLOGY (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Commissioning of an ultra-high dose rate pulsed electron beam medical LINAC for FLASH RT preclinical animal experiments and future clinical human protocols

Raphael Moeckli et al.

Summary: The study conducted acceptance and commissioning tests on an ultra-high dose rate electron device, showing good stability and compliance with company acceptance protocol. Measurements of PDDs, profiles, and reference dosimetry were carried out at two positions, demonstrating satisfactory results for FLASH RT experiments and protocols.

MEDICAL PHYSICS (2021)

Article Oncology

Irradiation at Ultra-High (FLASH) Dose Rates Reduces Acute Normal Tissue Toxicity in the Mouse Gastrointestinal System

Jia-Ling Ruan et al.

Summary: The study showed that FLASH irradiation can spare mouse small intestinal crypts and reduce changes in gut microbiome composition compared with CONV irradiation. The higher the average dose rate, the larger the FLASH effect, which is also influenced by the temporal pulse structure of the delivery.

INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Dosimetry with a clinical linac adapted to FLASH electron beams

Stanislaw Szpala et al.

Summary: Dosimetric measurements were conducted to assess a linac converted to FLASH dose rates, demonstrating the usability of Gafchromic EBT-XD film and dose rate-corrected cc13 ionization chamber. The performance of the modified linac was found adequate for FLASH radiobiological experiments, with different beam properties and dose rate dependencies observed.

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS (2021)

Review Oncology

Ultra-High Dose Rate (FLASH) Radiotherapy: Silver Bullet or Fool's Gold?

Joseph D. Wilson et al.

FRONTIERS IN ONCOLOGY (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

The European Joint Research Project UHDpulse - Metrology for advanced radiotherapy using particle beams with ultra-high pulse dose rates

Andreas Schueller et al.

PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS (2020)

Article Physics, Multidisciplinary

Calorimeter for Real-Time Dosimetry of Pulsed Ultra-High Dose Rate Electron Beams

Alexandra Bourgouin et al.

FRONTIERS IN PHYSICS (2020)

Article Oncology

Modifying a clinical linear accelerator for delivery of ultra-high dose rate irradiation

Michael Lempart et al.

RADIOTHERAPY AND ONCOLOGY (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Simulation and experimental validation of a prototype electron beam linear accelerator for preclinical studies

Pierre Lansonneur et al.

PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS (2019)

Article Multidisciplinary Sciences

Long-term neurocognitive benefits of FLASH radiotherapy driven by reduced reactive oxygen species

Pierre Montay-Gruel et al.

PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA (2019)

Article Oncology

Clinical translation of FLASH radiotherapy: Why and how?

Jean Bourhis et al.

RADIOTHERAPY AND ONCOLOGY (2019)

Article Oncology

Treatment of a first patient with FLASH-radiotherapy

Jean Bourhis et al.

RADIOTHERAPY AND ONCOLOGY (2019)

Article Instruments & Instrumentation

Time-resolved dosimetry of pulsed electron beams in very high dose-rate, FLASH irradiation for radiotherapy preclinical studies

Vincent Favaudon et al.

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2019)

Proceedings Paper Engineering, Biomedical

The Metrological Electron Accelerator Facility (MELAF) for Research in Dosimetry for Radiotherapy

Andreas Schueller et al.

WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 3 (2019)

Article Oncology

Experimental Platform for Ultra-high Dose Rate FLASH Irradiation of Small Animals Using a Clinical Linear Accelerator

Emil Schuler et al.

INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS (2017)

Article Radiology, Nuclear Medicine & Medical Imaging

High dose-per-pulse electron beam dosimetry: Usability and dose-rate independence of EBT3 Gafchromic films

Maud Jaccard et al.

MEDICAL PHYSICS (2017)

Article Radiology, Nuclear Medicine & Medical Imaging

High dose-per-pulse electron beam dosimetry - A model to correct for the ion recombination in the Advanced Markus ionization chamber

Kristoffer Petersson et al.

MEDICAL PHYSICS (2017)

Article Oncology

The FLUKA Code: An Accurate Simulation Tool For Particle Therapy

Giuseppe Battistoni et al.

FRONTIERS IN ONCOLOGY (2016)

Article Engineering, Biomedical

Uncertainties in alanine/ESR dosimetry at the Physikalisch-Technische Bundesanstalt

Mathias Anton

PHYSICS IN MEDICINE AND BIOLOGY (2006)