4.4 Article

Small static radiosurgery field dosimetry with small volume ionization chambers

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Article Radiology, Nuclear Medicine & Medical Imaging

Field output factors for small fields: A large multicentre study

S. Dufreneix et al.

Summary: A working group of the French medical physicist society was created to collect small field output factors from 23 centers, with standard deviations of mean factors ranging from less than 1.5% to 5%. The data obtained can serve as external cross verification and help minimize systematic errors in determining small field output factors for SRT programs.

PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

The influence of basic plan parameters on calculated small field output factors-A multicenter study

Maria Daniela Falco et al.

Summary: In this study, the influence of basic plan parameters on calculated small field output factors was evaluated, with modern treatment planning systems slightly overestimating the calculated OFs. Results indicated that grid resolution, algorithm, center number, and field size are factors that influence the calculation of small field output factors.

PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

On the evaluation of edgeless diode detectors for patient-specific QA in high-dose stereotactic radiosurgery

Elena De Martin et al.

Summary: The study evaluated the potential of an innovative edgeless silicon diode for patient-specific radiosurgery treatment plan verification, showing good performance in reference dosimetry data. This angular independent technology can be used for treatments in non-coplanar, non-isocentric stereotactic radiosurgery modalities.

PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

A Monte Carlo study on the PTW 60019 microDiamond detector

Guenther H. Hartmann et al.

MEDICAL PHYSICS (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

An EGS Monte Carlo model for Varian TrueBEAM treatment units: Commissioning and experimental validation of source parameters

Miguel Lopez-Sanchez et al.

PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Spatial response of synthetic microDiamond and diode detectors measured with kilovoltage synchrotron radiation

Duncan J. Butler et al.

MEDICAL PHYSICS (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

The polarity effect of compact ionization chambers used for small field dosimetry

Hui Khee Looe et al.

MEDICAL PHYSICS (2018)

Article Engineering, Biomedical

Is the PTW 60019 microDiamond a suitable candidate for small field reference dosimetry?

Vanessa De Coste et al.

PHYSICS IN MEDICINE AND BIOLOGY (2017)

Article Engineering, Biomedical

On the Monte Carlo simulation of small-field micro-diamond detectors for megavoltage photon dosimetry

Pedro Andreo et al.

PHYSICS IN MEDICINE AND BIOLOGY (2016)

Article Radiology, Nuclear Medicine & Medical Imaging

Polarity effects and apparent ion recombination in microionization chambers

Jessica R. Miller et al.

MEDICAL PHYSICS (2016)

Article Radiology, Nuclear Medicine & Medical Imaging

Experimental determination of the PTW 60019 microDiamond dosimeter active area and volume

Marco Marinelli et al.

MEDICAL PHYSICS (2016)

Article Radiology, Nuclear Medicine & Medical Imaging

Small field output factors evaluation with a microDiamond detector over 30 Italian centers

Serenella Russo et al.

PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS (2016)

Article Engineering, Biomedical

Properties of a commercial PTW-60019 synthetic diamond detector for the dosimetry of small radiotherapy beams

Jose Manuel Larraga-Gutierrez et al.

PHYSICS IN MEDICINE AND BIOLOGY (2015)

Article Radiology, Nuclear Medicine & Medical Imaging

Dosimetric characterization of a synthetic single crystal diamond detector in clinical radiation therapy small photon beams

I. Ciancaglioni et al.

MEDICAL PHYSICS (2012)

Article Radiology, Nuclear Medicine & Medical Imaging

Efficiency improvements for ion chamber calculations in high energy photon beams

J. Wulff et al.

MEDICAL PHYSICS (2008)

Article Radiology, Nuclear Medicine & Medical Imaging

Response to high-energy photons of PTW31014 PinPoint ion chamber with a central aluminum electrode

S. Agostinelli et al.

MEDICAL PHYSICS (2008)

Article Computer Science, Interdisciplinary Applications

The change of response of ionization chambers in the penumbra and transmission regions:: impact for IMRT verification

D. Gonzalez-Castano et al.

MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING (2008)

Article Radiology, Nuclear Medicine & Medical Imaging

An EGSnrc Monte Carlo study of the microionization chamber for reference dosimetry of narrow irregular IMRT beamlets

R Capote et al.

MEDICAL PHYSICS (2004)

Article Radiology, Nuclear Medicine & Medical Imaging

The behavior of several microionization chambers in small intensity modulated radiotherapy fields

M Stasi et al.

MEDICAL PHYSICS (2004)

Article Radiology, Nuclear Medicine & Medical Imaging

An investigation of the operating characteristics of two PTW diamond detectors in photon and electron beams

C De Angelis et al.

MEDICAL PHYSICS (2002)