HeLLePhant: A phantom mimicking non-small cell lung cancer for texture analysis in CT images

期刊

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.ejmp.2022.03.010

关键词

Radiomics; Phantom; PET-G; Polyacrylate

资金

  1. Italian Ministry of Health [GR-2016-02362050]
  2. Regione Lombardia under the Program Call Hub Ricerca e Innovazione (POR-FESR) [1170989-PRINTMED-3D, UID 2412, 11/05/2020]
  3. AIM-INFN project

向作者/读者索取更多资源

This study demonstrates a promising approach for constructing heterogeneous inserts mimicking target tissue for radiomic studies. The inserts made of polyacrylate show the best similarity with patients, while the Catphan inserts show the worst similarity. All the inserts in the HeLLePhant phantom have high repeatability.
Purpose: Phantoms mimicking human tissue heterogeneity and intensity are required to establish radiomic features robustness in Computed Tomography (CT) images. We developed inserts with two different techniques for the radiomic study of Non-Small Cell Lung Cancer (NSCLC) lesions. Methods: We developed two insert prototypes: two 3D-printed made of glycol-modified polyethylene terephthalate (PET-G), and nine with sodium polyacrylate plus iodinated contrast medium. The inserts were put in a handcraft phantom (HeLLePhant). We also analysed four materials of a commercial homogeneous phantom (Catphan (R) 424) and collected 29 NSCLC patients for comparison. All the CT acquisitions were performed with the same clinical protocol and scanner at 120kVp. The HeLLePhant phantom was scanned ten times in fixed condition at 120kVp and 100kVp for repeatability investigation. We extracted 153 radiomic features using Pyradiomics. To compare the features between phantoms and patients, we computed how many phantom features fell in the range between 10th and 90th percentile of the corresponding patient values. We deemed repeatable the features with a coefficient of variation (CV) less than or equal to 0.10. Results: The best similarity with the patients was obtained with the polyacrylate inserts (55.6-90.2%), the worst with Catphan (15.7-19.0%). For the PET-G inserts 35.3% and 36.6% of the features match the patient range. We found high repeatability for all the inserts of the HeLLePhant phantom (74.3-100% at 120kVp, 75.7-97.9% at 100kVp), and observed a texture dependency in repeatability. Conclusions: Our study shows a promising way to construct heterogeneous inserts mimicking a target tissue for radiomic studies.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据