4.2 Article

Muscarinic-3-receptor positive allosteric modulator ASP8302 in patients with underactive bladder. A randomized controlled trial

期刊

NEUROUROLOGY AND URODYNAMICS
卷 41, 期 5, 页码 1139-1148

出版社

WILEY
DOI: 10.1002/nau.24931

关键词

lower urinary tract symptoms; muscarinic receptor M3; randomized controlled trial; underactive bladder

资金

  1. Astellas Pharma Europe B.V., BE Leiden, The Netherlands

向作者/读者索取更多资源

This study aimed to evaluate the safety and efficacy of ASP8302, a novel positive allosteric modulator for the muscarinic M3 receptor (M3-PAM), in patients with underactive bladder (UAB). Results showed improvement of symptoms and functional parameters in male patients, but no significant efficacy in the primary endpoint was observed.
Aim The aim of this study is to evaluate safety and efficacy of ASP8302, a novel positive allosteric modulator for the muscarinic M3 receptor (M3-PAM), in patients with underactive bladder (UAB). Methods A randomized, double-blind, placebo-controlled multicenter study was performed in adult male/female subjects with UAB, defined as incomplete bladder emptying (postvoid residual volume [PVR] > 100 ml) without significant bladder outlet obstruction and/or overactive bladder. Subjects were randomized (1:1) to receive 4-week oral once-daily administration of 100 mg ASP8302 or matching placebo. Primary endpoint was a change from baseline in PVR measured by catheterization after standardized bladder filling (PVRC2). Other endpoints included PVR and bladder voiding efficiency (BVE) measured in various ways, uroflowmetry, bladder diary, and questionnaires. Pressure-flow studies were performed in a subgroup. Results One hundred and thirty-five patients were randomized (ASP8302 group: 65 patients, placebo group: 70 patients). The median change in PVRC2 was -40.0 ml (ASP8302) versus -35.0 ml (placebo) and the difference between groups was -5.0 ml (p = 0.960). In males, functional and symptomatic outcomes improved, for example, maximum urine flow rate (Q(max)) and detrusor pressure at Q(max) (P-det.Qmax) increased (mean difference in change ASP8302 vs. placebo: 3.8 ml/s, p = 0.031 and 12.7 cm H2O, p = 0.034, respectively). Urinary incontinence episodes/24 h decreased in males with preexisting incontinence (mean difference: -0.35; p = 0.028). The incidence of adverse events was similar between study groups (ASP8302: 33.3%, placebo: 31.4%). In the included subjects, both baseline urine flow and bladder voiding pressure was low. Compared with PVR, simultaneous BVE measurements were more consistent between various methods (spontaneous vs. standardized bladder filling, catheterization vs. ultrasound [US]). Conclusions ASP8302 was safe and well tolerated in patients with UAB identified by nonurodynamic clinical criteria, but it did not show efficacy in the primary endpoint. However, in males it showed improvement of symptoms and functional parameters. BVE (using US) is a more optimal outcome measure than PVR in UAB.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据