4.6 Article

Portable Digital Linear Ion Trap Mass Spectrometer Based on Separate-Region Corona Discharge Ionization Source for On-Site Rapid Detection of Illegal Drugs

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Article Biochemical Research Methods

The metabolism of the synthetic cannabinoids ADB-BUTINACA and ADB-4en-PINACA and their detection in forensic toxicology casework and infused papers seized in prisons

Robert Kronstrand et al.

Summary: The study identified an increasing prevalence of the synthetic cannabinoid receptor agonist ADB-BUTINACA and recommended specific metabolites in blood and urine as biomarkers. Another SCRA, ADB-4en-PINACA, was also discovered with a lower prevalence, and metabolites E3 and E7 were suggested as biomarkers.

DRUG TESTING AND ANALYSIS (2022)

Article Physics, Atomic, Molecular & Chemical

Assessing the environmental ruggedness of paper spray ionization (PSI) coupled to a portable mass spectrometer operated under field conditions

Ashley R. Stelmack et al.

Summary: This study systematically characterized the performance of paper spray ionization-mass spectrometry (PSI-MS) under variable environmental conditions, finding that wind speeds greater than 3 m/s had the most significant impact on PSI-MS spectral attributes, while moderate ambient temperature and %RH produced the best spectral performance.

INTERNATIONAL JOURNAL OF MASS SPECTROMETRY (2022)

Article Biochemistry & Molecular Biology

Spherical Sampler Probes Enhance the Robustness of Ambient Ionization Mass Spectrometry for Rapid Drugs Screening

Mariya A. Shamraeva et al.

Summary: Ambient ionization mass spectrometry is a promising method for screening small molecules in complex biological matrices. Efforts have been made to simplify procedures and improve the robustness and sensitivity of the methods. The use of rigid spherical sampler probes in touch spray ionization mass spectrometry improves stability, reduces requirements for positioning, and allows for rapid analysis of various drugs in complex biological matrices.

MOLECULES (2022)

Review Spectroscopy

FIELDABLE MASS SPECTROMETRY FOR FORENSIC SCIENCE, HOMELAND SECURITY, AND DEFENSE APPLICATIONS

Kenyon Evans-Nguyen et al.

Summary: Mass spectrometry is widely used in forensic chemistry laboratories, with efforts to develop ruggedized, fieldable instruments for on-site analysis. Testing samples in the field is of particular interest in forensic science, homeland security, and defense applications. Mass spectrometry is well suited for providing definitive answers with low false positive rates in homeland security and military applications.

MASS SPECTROMETRY REVIEWS (2021)

Article Chemistry, Analytical

Screening of seized drugs utilizing portable Raman spectroscopy and direct analysis in real time-mass spectrometry (DART-MS)

Travon Cooman et al.

Summary: The study utilized portable Raman spectroscopy and direct analysis in real time mass spectrometry (DART-MS) for screening and analysis of seized drug samples, achieving an overall accuracy of 96%. The identification accuracy for mixture samples reached 92%, while the combined accuracy for authentic case samples was 83%.

FORENSIC CHEMISTRY (2021)

Article Chemistry, Analytical

Pressure-Sensitive Adhesive Combined with Paper Spray Mass Spectrometry for Low-Cost Collection and Analysis of Drug Residues

Chau Bao Nguyen et al.

Summary: Illicit drug use causes over 500,000 deaths worldwide annually, highlighting the need for improved methods to detect trace drug residues on surfaces. This study utilized commercially produced paper with a pressure-sensitive adhesive coating for the collection and analysis of trace drug residues through paper spray mass spectrometry, enabling rapid detection on various surfaces.

ANALYTICAL CHEMISTRY (2021)

Article Biochemical Research Methods

Using gas-phase chloride attachment for selective detection of morphine in a morphine/codeine mixture by ion mobility spectrometry

Younes Valadbeigi et al.

Summary: Morphine and codeine, two important compounds in the opiate family, were selectively detected using ion mobility spectrometry equipped with a negative ion mode. Due to differences in their structures, morphine, with a phenolic OH group, is more acidic and has greater anion-receiving capability compared to codeine, which only has an alcoholic OH group. Therefore, morphine can both be deprotonated and form an adduct anion with Cl- in the presence of chloroform, while codeine cannot.

RAPID COMMUNICATIONS IN MASS SPECTROMETRY (2021)

Review Biochemistry & Molecular Biology

Nontargeted Screening Using Gas Chromatography-Atmospheric Pressure Ionization Mass Spectrometry: Recent Trends and Emerging Potential

Xiaolei Li et al.

Summary: Gas chromatography-high-resolution mass spectrometry (GC-HRMS) is a powerful nontargeted screening technique that shows promise in accelerating the identification of environmental pollutants. The use of atmospheric pressure ionization (API) ion sources in GC-HRMS instruments provides advantages such as improved detection limits and structure diagnostic ion-molecule reactions, although the lack of spectral libraries may be a drawback.

MOLECULES (2021)

Article Medical Laboratory Technology

Urinary Metabolite Biomarkers for the Detection of Synthetic Cannabinoid ADB-BUTINACA Abuse

Chi Hon Sia et al.

Summary: The study characterized the metabolites of ADB-BUTINACA in human liver microsomes using liquid chromatography Orbitrap mass spectrometry analysis, determining the metabolic pathways and elimination mechanisms of the substance. By combining in vitro metabolism and urinary analysis, four urinary metabolite biomarkers of ADB-BUTINACA were identified.

CLINICAL CHEMISTRY (2021)

Article Physics, Atomic, Molecular & Chemical

Rapid identification of illegal drugs and explosives using resonance excitation in miniaturized photoionization ion trap mass spectrometry

Weimin Wang et al.

Summary: Illegal drugs and explosives are harmful chemicals that pose social and national security threats. Miniaturized photoionization ion trap mass spectrometry is effective for rapid identification; this study successfully analyzed fragments of 22 illegal drugs and 7 explosives and established a database to rapidly identify substances within 3 seconds using tandem mass spectrometry.

INTERNATIONAL JOURNAL OF MASS SPECTROMETRY (2021)

Review Biochemistry & Molecular Biology

Roadside Drug Testing Approaches

Manal A. Alhefeiti et al.

Summary: This review presents an overview of roadside drug testing, driving enforcement, and drunk/drug driving detection worldwide. It highlights the implications of drunk or drug driving on road safety, the introduction of mobile roadside drug testing devices, and the use of oral fluid by law enforcement agencies. The article also discusses the types of drugs abused by drivers, behavioral testing methods, and sample collection and analysis procedures.

MOLECULES (2021)

Article Chemistry, Multidisciplinary

Thermal Decomposition of Cocaine and Methamphetamine Investigated by Infrared Spectroscopy and Quantum Chemical Simulations

Martin Ferus et al.

Summary: The examination of thermal decomposition of street samples of cocaine and methamphetamine revealed a wide range of volatile compounds that can be easily detected by Fourier-transform infrared (FTIR) spectrometry. The study also involved theoretical analysis of the decomposition mechanism using quantum-chemical calculations, and characterization of the samples using various spectroscopic techniques before analysis.

ACS OMEGA (2021)

Article Chemistry, Analytical

Investigation of the effect of an octopole electric field on a linear ion trap and an asymmetric semi-circular linear ion trap analyzer

Fuxing Xu et al.

Summary: The study investigated the effect of octopole field on the linear quadrupole ion trap through theoretical simulations and experiments, resulting in the design and testing of an asymmetric semi-circular linear ion trap (AsC-LIT). Experimental results showed significant improvement in mass resolution and CID efficiency with the addition of positive octopole field. Theoretical simulations suggested that a 2.56% octopole component was optimal for higher analytical performances.

ANALYST (2021)

Article Biochemical Research Methods

Implementation and study of dopant-assisted photoionization with a miniature capillary inlet ion trap mass spectrometer

Qian Zhang et al.

RAPID COMMUNICATIONS IN MASS SPECTROMETRY (2020)

Article Chemistry, Analytical

On-site testing of multiple drugs of abuse in urine by a miniature dual-LIT mass spectrometer

Manqing Kang et al.

ANALYTICA CHIMICA ACTA (2020)

Article Chemistry, Analytical

Reactive Olfaction Ambient Mass Spectrometry

Dmytro S. Kulyk et al.

ANALYTICAL CHEMISTRY (2019)

Article Chemistry, Analytical

High-Resolution Ion Mobility Spectrometry for Rapid Cannabis Potency Testing

Marianne Hadener et al.

ANALYTICAL CHEMISTRY (2018)

Article Chemistry, Analytical

Bomb swab: Can trace explosive particle sampling and detection be improved?

Danny Fisher et al.

TALANTA (2017)

Article Chemistry, Analytical

A hand-portable digital linear ion trap mass spectrometer

Bing Xue et al.

ANALYST (2016)

Article Biochemical Research Methods

Design and Performance Evaluation of a Linear Ion Trap Mass Analyzer Featuring Half Round Rod Electrodes

Xiaoxu Li et al.

JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY (2015)

Article Chemistry, Analytical

Novel Linear Ion Trap Mass Analyzer Built with Triangular Electrodes

Yu Xiao et al.

ANALYTICAL CHEMISTRY (2014)

Article Chemistry, Analytical

Handheld Low-Temperature Plasma Probe for Portable Point-and-Shoot Ambient Ionization Mass Spectrometry

Joshua S. Wiley et al.

ANALYTICAL CHEMISTRY (2013)

Article Biochemical Research Methods

Alternating current corona discharge/atmospheric pressure chemical ionization for mass spectrometry

Ahsan Habib et al.

RAPID COMMUNICATIONS IN MASS SPECTROMETRY (2013)

Article Biochemical Research Methods

Digital Asymmetric Waveform Isolation (DAWI) in a Digital Linear Ion Trap

Francesco L. Brancia et al.

JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY (2010)

Article Chemistry, Analytical

Low-Temperature Plasma Probe for Ambient Desorption Ionization

Jason D. Harper et al.

ANALYTICAL CHEMISTRY (2008)

Review Multidisciplinary Sciences

Ambient mass spectrometry

RG Cooks et al.

SCIENCE (2006)

Article Chemistry, Analytical

Versatile new ion source for the analysis of materials in open air under ambient conditions

RB Cody et al.

ANALYTICAL CHEMISTRY (2005)

Article Biochemical Research Methods

A digital ion trap mass spectrometer coupled with atmospheric pressure ion sources

L Ding et al.

JOURNAL OF MASS SPECTROMETRY (2004)

Article Physics, Atomic, Molecular & Chemical

A simulation study of the digital ion trap mass spectrometer

L Ding et al.

INTERNATIONAL JOURNAL OF MASS SPECTROMETRY (2002)

Article Biochemical Research Methods

A two-dimensional quadrupole ion trap mass spectrometer

JC Schwartz et al.

JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY (2002)