This study investigates the comparative effects of different semiconductor materials, device structures, and X-ray incident power on the performance of mesa p(+)-i-n(+) photodiodes for X-ray-voltaics. The GaAs device shows the highest short circuit current, while the 10 μm AlInP device exhibits the highest open circuit voltage. The InGaP device achieves the greatest output X-ray power due to its high fill factor.
Five mesa p(+)-i-n(+) photodiodes (each of 0.126 mm(2) area) were investigated as conversion devices for X-ray-voltaics, in order to understand the comparative effects between different semiconductor materials, device structures, and X-ray incident power, and to explore them for use in future radioisotope microbatteries. Three semiconductor materials (AlInP, InGaP, and GaAs) and three i layer thicknesses of one material, AlInP (2 mu m, 6 mu m, and 10 mu m), were investigated under the illumination of various controlled X-ray incident powers. The highest short circuit current was achieved with the GaAs device due to its thickest active layer and highest linear absorption coefficients at the most numerous incident X-ray photon energies (Mo K alpha at 17.48 keV; Mo K beta at 19.6 keV). The highest open circuit voltage was achieved with the 10 mu m AlInP device due to its widest bandgap (cf. InGaP and GaAs) and its highest short circuit current (cf. the 2 mu m and the 6 mu m AlInP devices). The greatest output X-ray power was recorded with the InGaP device due to its highest fill factor (i.e. relatively low series and high shunt resistance) compared to the rest of the devices, although the GaAs device had the highest theoretical output X-ray power. A method for selecting the most suitable semiconductor material and device structure of conversion devices for radioisotope microbatteries (for exhibiting the highest power output) is presented considering the incident X-ray spectrum, while highlighting the importance of non-ideal device effects (reduced charge collection efficiency, increased series resistance, and reduced shunt resistance).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据