期刊
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS
卷 215, 期 -, 页码 -出版社
ELSEVIER
DOI: 10.1016/j.jpba.2022.114762
关键词
Colorectal cancer; Free fatty acids (FFA); SCFA; MCFA; ID/GC-MS
资金
- Progetto di Sviluppo Dipartimentale DiSCOG (Progetto Biobanca-University of Padua)
This study developed a new analysis method to simultaneously quantify short-chain fatty acids (SCFAs) and medium-chain fatty acids (MCFAs) in plasma as specific markers for the microbiota and host metabolic alterations. The method is simple, efficient, and shows high accuracy and precision.
The targeted analysis of free fatty acids (FFAs) is attractin g interest since several years with a plenty of studies. However, most of them are devoted to the solely determination of the short-chain fatty acids (SCFAs) arising from the symbiotic gut microbiota metabolism. Recently, the FFAs analysis highlighted changes in the plasma levels of octanoic and decanoic acids (medium-chain fatty acids or MCFAs) may be associated to gastrointestinal diseases, including colorectal cancer (CRC). Then, the simultaneous quantification of both SCFAs and MCFAs could be usef u l to put in evidence the interconnection between microbiota and metabolic alterations during hosts' disease. To this aim, it was developed an isotopic dilution gas-chromatography coupled mass spectrometr y (ID/GC-MS) method for the targeted analysis of both linear and branched FFAs (SCFAs, MCFAs, and LCFAs) in human plasma samples as specific markers for both microbiota and host metabolic alterations. In order to minimize sample manipulation procedures, an efficient, sensible and low time-consuming procedure is pre-sented, which relies in a simple liquid-liquid extraction before the determination of underivatized free acids (FFAs) by Single Ion Monitoring (SIM) acquisition. The reached detection limits (LODs) were less than 100 mu g L-1 for most of analytes, except for acetic, hexadecanoic and octadecanoic acids that showed a LOD > 1 mg L-1. Methods accuracy and precision, obtained by the analysis of the FFAs mixtures showed accuracy values between 84% and 100% and precision (RSD %) between 0.1% and 12.4% at the concentration levels tested. The proposed ID/GC-MS method was applied in a case study to evaluate the FFAs as specific markers for both microbiota and host alterations in CRC patients. Obtained results highlight the advantage of present method for its rapidit y , simplicity, and robustness.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据