4.3 Article Proceedings Paper

Optimization of pixel size and propagation distance in X-ray phase-contrast virtual histology

期刊

JOURNAL OF INSTRUMENTATION
卷 17, 期 5, 页码 -

出版社

IOP Publishing Ltd
DOI: 10.1088/1748-0221/17/05/C05021

关键词

Computerized Tomography (CT) and Computed Radiography (CR); X-ray detectors; Inspection with X-rays

资金

  1. Italian Ministry of University and Research [PIR01_00008]

向作者/读者索取更多资源

X-ray phase-contrast coupled with high-spatial resolution imaging systems allows for the distinction of soft tissue structures in small samples, making it suitable for X-ray virtual histology. This study optimized acquisition parameters and used a suitable phase retrieval filter to achieve virtual histology imaging of breast surgery specimens.
X-ray phase-contrast coupled to high-spatial resolution imaging systems provides a high sensitivity for distinguishing soft tissue structures in small samples, thus being suited for X-ray virtual histology. Propagation-based phase-contrast tomography can deliver a considerable gain in signal-to-noise ratio (SNR) at small pixel sizes when it is combined to a suitable phase retrieval filter. We optimized acquisition parameters, namely the propagation distance and the pixel size, with the aim of providing adequate spatial resolution and sensitivity for virtual histology of breast surgery specimens, scanned with a phase-contrast microtomography (mu CT) system employing a commercial sCMOS detector at the SYRMEP beamline of the Italian synchrotron facility Elettra (Trieste, Italy). A pathological breast tissue sample was embedded in paraffin and imaged using a polychromatic synchrotron beam at an average energy of 24 keV. The high numerical optical aperture of the imaging system enabled to adjust the pixel size to 1, 2.5 and 4 mu m. The scans were acquired at five sample-to-detector distances: 4.5, 150, 250, 500 and 1000 mm. SNR was measured in an homogeneous region portion of the mu CT image for each combination of pixel size and propagation distance. Experimental results were compared to a theoretical model taking into account the actual point spread function of the employed imaging system. The measured gain of SNR associated with the application of the phase-retrieval matched the predictions for large Fresnel numbers (N-F > 2). For each pixel size, an optimal range of propagation distances was found. Optimal mu CT reconstructions were then compared with their respective histopatological images, showing an excellent visibility of relevant structures. The optimization performed in this study will allow to select the most appropriate geometrical configurations for future acquisitions of virtual histology images of different specimens via phase-contrast microtomography.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据