期刊
JOURNAL OF HYDROINFORMATICS
卷 24, 期 3, 页码 697-710出版社
IWA PUBLISHING
DOI: 10.2166/hydro.2022.005
关键词
active set method; constrained emitter method; EPANET 2; 2; global gradient approach; pressure-driven analysis; water distribution networks
This study compares the performance of several alternative pressure-driven analysis methods in the EPANET water distribution system modeling software. The results show that all the new inverse methods are equally efficient and reliable, while the direct method has a higher frequency of failing to converge.
This work compares several alternative methods of pressure-driven analysis (PDA) implemented within the code base of the EPANET water distribution system modeling software. The resulting code includes a direct method, the original and a newly modified version of the inverse method currently used by EPANET 2.2, and two recently published methods (the global gradient approach-based PDA and the active set method). The latter four methods solve PDA problems using an inverse flow-pressure relationship, whereas the direct method uses the original relationship. The alternative methods were extensively tested, and their performance was compared over several case study water distribution networks of vastly different sizes and complexities. The results showed that all of the new inverse methods are equally efficient and reliable, whereas the direct method is less reliable by having a higher frequency of failing to converge.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据