4.7 Article

A new ratiometric electrochemical aptasensor for the sensitive detection of carcinoembryonic antigen based on exonuclease I-assisted target recycling and hybridization chain reaction amplification strategy

期刊

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.jelechem.2022.116167

关键词

Ratiometric electrochemical aptasensor; Carcinoembryonic antigen; Exonuclease; Target recycling; Hybridization chain reaction

资金

  1. National Natural Science Founda-tion of China [61701171]
  2. Key Research Programs for Institu-tions of Higher Education in Henan Province [20A180010]

向作者/读者索取更多资源

In this work, a novel ratiometric electrochemical aptasensor based on dual-amplification mechanism was designed. The aptasensor showed high specificity, stability, and reproducibility. Furthermore, it can be applied for the detection of other targets.
In this work, a novel ratiometric electrochemical aptasensor was designed on the basis of dual-amplification mechanism by using exonuclease I (Exo I)-assisted target recycling and hybridization chain reaction (HCR). The thiol-modified capture DNA (Cp-DNA) was fixed on the surface of the gold electrode (AuE) modified with gold nanoparticles (AuNPs) through Au-S bonds. The ferrocene (Fc)-labeled DNA (Fc-DNA) hybridized with Cp-DNA to form Fc-DNA/Cp-DNA duplex. The presence of carcinoembryonic antigen (CEA) led to the dissociation of Fc-DNA from Fc-DNA/Cp-DNA duplex and initiated Exo I-assisted target recycling to digest Fc-DNA, so numerous Fc left away from the electrode surface and resulting in the signal off of Fc. Moreover, Cp-DNA was exposed to bind trigger DNA and initiate HCR with the presence of H1 and H2 probes, resulting in the intercalating of numerous methylene blue (MB) molecules and the signal-on of MB. This dual signal strategy significantly amplified the decrease of Fc signal and the increase of MB signal, achieving a linear range of 1 pg mL(-1) to 100 ng mL(-1) with a detection limit of 0.479 pg mL(-1) (S/N = 3). Besides, the developed aptasensor exhibited high specificity, good stability and reproducibility. More importantly, the aptasensor had been applied in detection of CEA in diluted human serum and displayed satisfactory anti-interference property. By changing the corresponding aptamer sequences, the designed strategy can be employed to detect other targets, which holds promising application in clinical diagnosis.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据