4.6 Article

A novel approach to assess volumetric bone loss at immediate implant sites and comparison to linear measurements: A pilot study

期刊

JOURNAL OF DENTISTRY
卷 120, 期 -, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.jdent.2022.104083

关键词

CBCT imaging; Immediate implants; Alveolar bone remodeling; Digital dentistry

向作者/读者索取更多资源

This study compared the 3D volumetric changes of peri-implant bone at immediate implant sites with 2D linear measurements. The results showed that linear measurements could not fully represent volumetric bone dimensional changes. Volumetric measurements and 3D rendering were valuable in presenting the actual amount and topography of peri-implant bone remodeling.
Objectives: Studies have evaluated changes in hard tissue following immediate implant placement (IIP) through cone beam computed tomography (CBCT) imaging. This study compared the 3D volumetric changes of the alveolar bone at immediate implant sites with 2D linear measurement outcomes by using a novel image analysis workflow. Methods: Preoperative and 6-month postoperative CBCT images of patients who underwent IIP and bone grafting in the maxillary esthetic area were acquired. Linear and volumetric measurements of buccal bone dimensions were taken using a specially designed workflow. The 2D and 3D measurements were compared, and their correlations were determined. Results: Images from 13 patients (13 implants) were analyzed. Linear measurements revealed that the general linear buccal bone loss was less than 1mm in all segments. The 3D volumetric bone reduction (reported as median [first quantile, third quantile]) in the vertical, cervical, middle, and apical segments was 14.27 [11.33, 30.66] mm(3) (51.30 [42.78, 66.91]%), 16.20 [10.35, 30.52] mm(3) (18.20 [9.88, 24.74]%), 17.48 [8.42, 21.17] mm(3) (24.05 [12.39, 28.22]%), and 6.87 [3.88, 9.45] mm(3) (11.34 [5.14, 22.54]%), respectively. Significant positive correlations between 2D and 3D measurements were consistently identified in the cervical and middle segments, but no significant correlation was noted in the vertical segment. Conclusions: The results revealed that linear measurements could not fully represent volumetric bone dimensional changes. Performing volumetric measurements and 3D rendering could be valuable in presenting the actual amount and topography of peri-implant bone remodeling. Clinical Significance: Linear measurements only partially represent the real-life event of 3D bone changes at immediate implant sites. Factors affecting hard tissue alterations following IIP should be reassessed using 3D volumetric measurement outcomes.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据