4.2 Article

Evaluation of neonatal hearing screening results of newborns with premature retinopathy

出版社

ELSEVIER IRELAND LTD
DOI: 10.1016/j.ijporl.2022.111112

关键词

Retinopathy of prematurity; Hearing screening; Newborn

向作者/读者索取更多资源

The study revealed that ROP patients have higher risk of hearing loss in newborn hearing screening, especially in stage 3 ROP patients. It is recommended to follow up the newborn hearing screenings of patients with advanced stage ROP more sensitively.
Objectives: To reveal the risk situations of ROP patients in terms of hearing loss by examining the newborn hearing screening test results. Methods: Hearing screening test results of ROP patients and newborns with similar congenital risk factors(control group) treated in our hospital were retrospectively screened. Both groups were compared in terms of newborn hearing screening test results. Results: In the first screening test, the rate of refer result in the ROP group was significantly higher than the control group (p < 0.05). There was no significant difference between the two groups in terms of second hearing screening test results (p > 0.05). In the second screening test, 100% of stage 3 ROP patients failed from the right ear and 80% in the left ear, and this difference was statistically significant compared to the other two groups (p < 0.05). Conclusion: Newborn hearing screenings of patients with advanced stage ROP patients should be followed up more sensitively, since stage 3 ROP patients had more failure results from the screening test in our study.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据