4.7 Article

A Two-Stage Simultaneous Control Scheme for the Transient Angle Stability of VSG Considering Current Limitation and Voltage Support

期刊

IEEE TRANSACTIONS ON POWER SYSTEMS
卷 37, 期 3, 页码 2137-2150

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TPWRS.2021.3121474

关键词

Transient analysis; Power system stability; Stability analysis; Impedance; Reactive power; Voltage control; Switches; Virtual synchronous generator; large-signal model; fault; transient angle stability; current limitation; voltage support

资金

  1. National Natural Science Foundation of China [52022035, TPWRS-00357-2021]

向作者/读者索取更多资源

This paper proposes a control scheme to improve the transient stability of VSG by considering the current limitation during fault state and voltage support after fault clearance, as well as an additional feedback control based on the fault signal. The effectiveness of the proposed method is verified under both symmetrical and asymmetrical faults, and its application in a multiple VSGs system is also verified.
Since the wide application of virtual synchronous generators (VSGs), the power grid faces great challenges in the safe and stable operation due to their limited thermal capacity and weak anti-disturbance ability. During transient period, for example, a fault occurs in the transmission line, the VSG may lose the transient angle stability and provoke the current hard limit. Even if the fault is cleared by tripping of line, it still faces the problem of instability and voltage dips. To address this problem, in this paper, the post-fault large-signal model of VSG is derived first via the travelling waves based fault information acquisition. Subsequently, with the effect of both active and reactive power loops taken into account, a two-stage simultaneous control scheme is proposed for improving the transient stability of VSG, while considering the current limitation during fault state and voltage support after fault clearance. This method is fulfilled by mode switching and an additional feedback control based on the fault signal. Finally, the effectiveness of the proposed method under both symmetrical and asymmetrical faults is verified. Moreover, the application of the proposed method in a multiple VSGs system is also verified. Besides, the robustness to parameter mismatch and the feasible operating region for the method are discussed.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据