4.4 Article

Algorithm of the major and minor diagnostic criteria for active myopic choroidal neovascularization

出版社

SPRINGER
DOI: 10.1007/s00417-022-05599-5

关键词

Myopic CNV; Diagnostic algorithm; Biomarkers; Sensitivity; Specificity

向作者/读者索取更多资源

This study aims to propose an algorithm for the major and minor diagnostic criteria of macular myopic choroidal neovascularization (mCNV). By analyzing clinical and imaging parameters in a retrospective study, it was found that a combination of at least four clinical and biological markers yielded the highest positive- and negative-predictive values.
Purpose To propose an algorithm of the major and minor diagnostic criteria for macular myopic choroidal neovascularization (mCNV). Methods This single-center, retrospective, cross-sectional study was based in Istituto Auxologico Italiano, Milan, Italy. Two authors evaluated the clinical and imaging parameters of eyes with high myopia (spherical equivalent of -6D or less) and suspected to have naive, recurrent, or inactive mCNV. Recordings of the eyes that met the inclusion criteria were then independently evaluated by two other senior retinal specialists. Fluorescein angiography (FA), spectral domain optical coherence tomography (SD-OCT), and OCT angiography were used for multimodal imaging. Results One-hundred and twenty-two eyes (n = 107; 39 men, 68 women) were included in the study. The mean patient age was 66 years (range, 22-89 years). There were 83 and 39 eyes in the active mCNV and control groups, respectively. The best diagnostic algorithm had positive- and negative-predictive values of 89% and 85%, respectively, and was based on four criteria: leakage/staining on FA, retinal thickening, fuzzy area on SD-OCT, and recent metamorphopsia. When excluding FA-derived findings, retinal pigment epithelium (RPE) features played a diagnostic role in 33 eyes (27%). Twenty-seven eyes with active mCNV (32%) did not have the fuzzy area. Taken singularly, no clinical or imaging parameter had both sensitivity and specificity greater than 78%. Matching of 2 or 3 biomarkers did not yield a sensitivity or specificity greater than 79%. Sensitivities and specificities >= 90% were found in ten criteria combinations that included four to five biomarkers. The most frequent were metamorphopsia, fuzzy area, retinal thickening, and leakage. Less frequently, they included hemorrhage, staining, and RPE features such as elevation, flattening, and focal interruption. For all the parameters, the agreement between the investigators was good (Cohen k >= 0.66), being the lowest when detecting the ELM interruption within the lesion. Conclusions A combination of at least four clinical and biological markers yielded the highest positive- and negative-predictive values. More (major) and less (minor) frequent diagnostic criteria are proposed.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据