4.5 Article

Determination of parabens in wastewater samples via robot-assisted dynamic single-drop microextraction and liquid chromatography-tandem mass spectrometry

期刊

ELECTROPHORESIS
卷 43, 期 15, 页码 1567-1576

出版社

WILEY
DOI: 10.1002/elps.202100390

关键词

automated sample preparation; liquid chromatography; liquid-phase microextraction; mass spectrometry; single-drop microextraction

资金

  1. Coordination for the Improvement of Higher Education Personnel (CAPES-Brazil) [001]
  2. Sao Paulo Research Foundation (FAPESP-Brazil) [2019/22724-7, 2017/02147-0, 2015/15462-5, 2014/07347-9]
  3. National Council for Scientific and Technological Development (CNPq-Brazil) [307293/2014-9, 308843/2019-3]
  4. Ministry of Science, Technology, and Innovation (MINCIENCIASColombia) [679]

向作者/读者索取更多资源

Dynamic single-drop microextraction (SDME) was automated using an Arduino-based Cartesian robot and combined with liquid chromatography-tandem mass spectrometry for the determination of parabens in wastewater samples. The robot-assisted technique facilitated the control of dynamic SDME, making the process more feasible, robust, and reliable. This setup proved to be a competitive strategy for the automated extraction of organic pollutants from water samples.
Dynamic single-drop microextraction (SDME) was automatized employing an Arduino-based lab-made Cartesian robot and implemented to determine parabens in wastewater samples in combination with liquid chromatography-tandem mass spectrometry. A dedicated Arduino sketch controls the auto-performance of all the stages of the SDME process, including syringe filling, drop exposition, solvent recycling, and extract collection. Univariate and multivariate experiments investigated the main variables affecting the SDME performance, including robot-dependent and additional operational parameters. Under selected conditions, limit of detections were established at 0.3 mu g/L for all the analytes, and the method provided linear responses in the range between 0.6 and 10 mu g/L, with adequate reproducibility, measured as intraday relative standard deviations (RSDs) between 5.54% and 17.94%, (n = 6), and inter-days RSDs between 8.97% and 16.49% (n = 9). The robot-assisted technique eased the control of dynamic SDME, making the process more feasible, robust, and reliable so that the developed setup demonstrated to be a competitive strategy for the automated extraction of organic pollutants from water samples.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据