Particle release from dental implants immediately after placement - An ex vivo comparison of different implant systems

期刊

DENTAL MATERIALS
卷 38, 期 6, 页码 1004-1014

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.dental.2022.04.003

关键词

Dental implant; Particle release; Wear; Commercial pure titanium; Titanium alloy; Ti-6Al-4V; Toxicity; Roxolid; Phagocytosis

向作者/读者索取更多资源

This study found that implants with wider body diameters released more metallic elements, with Ti-6Al-4V implants releasing significantly more compared to Ti-CP4 and Ti-15Zr. Ti-CP4 and Ti-15Zr appear to be more suitable materials, but further research is needed to elucidate the biological effects of these fine particles and/or metallic species.
Objectives: Metallic element release during implant placement can lead to mucositis and peri-implantitis. Here, using ex vivo porcine mandibles, the release of metallic elements into the surrounding bone with different material and geometrical designs was quantified. Methods: Implants from BioHorizons (R) and Straumann (R) (Bone level, tapered/cylindrical, 3/4 mm body diameter, Ti-CP4/Ti-6Al-4V/Ti-15Zr) systems were used. Micro computed tomography and inductively coupled plasma optical emission spectroscopy was used to visualise and quantify metallic elements in bone, following acid digestion. Implant surfaces were examined with scanning electron microscopy and internalization of implant particles by human gingival fibroblasts (HGFs) and RAW 264.7 macrophages were demonstrated in vitro. Results: Implants with wider body diameters resulted in higher metallic element release. Ti-6Al-4V implants released significantly more metallic elements in comparison to both Ti-CP4 and Ti-15Zr devices with similar design and dimensions. Tapered Ti-CP4 implants released less compared to those with cylindrical design. Al three types of particles were internalized by HGFs and RAW 264.7. Significance: Ti-CP4 and Ti-15Zr appear to be more suitable materials, however, further studies are required to elucidate the biological effects of the fine particles and/or metallic species from dental implants. Authors would like to raise the awareness in the dental profession community that careful evaluation of the materials used in dental implants and the potential risks of the individual constituents of any alloy are needed. The potential cytotoxicity of Ti-6Al-4V implant particles should be highlighted. Further investigations on the biological effect of the fine particles or metallic species released from dental implants are also needed. (C) 2022 The Authors. Published by Elsevier Inc. on behalf of The Academy of Dental Materials.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据