4.4 Article

Rapid Analytical Method Development and Validation for the Simultaneous Estimation of 5-Fluorouracil and Cannabidiol in Plasma and Lipid-based Nanoformulations

期刊

CURRENT ANALYTICAL CHEMISTRY
卷 18, 期 7, 页码 798-808

出版社

BENTHAM SCIENCE PUBL LTD
DOI: 10.2174/1573411018666220304085236

关键词

5-Fluorouracil; cannabidiol; HPLC; method validation; simultaneous estimation; nanoformulations

资金

  1. Indian Council of Medical Research (ICMR) [45/19/2020-Nan/BMS]
  2. University Grants Commission (UGC)
  3. Indian Council of Medical Research (ICMR), New Delhi, India [35/10/2019-Nano/BMS, 5/13/8/2020/NCD-III]
  4. University Grants Commission (UGC), New Delhi, India

向作者/读者索取更多资源

The paper describes the development and validation of a simple and reliable HPLC method for simultaneous estimation of 5-FU and CBD. The method showed good linearity, precision, specificity, and robustness. It could be effectively used for quantification of these drugs in various in vitro and in vivo studies.
Background: 5-Fluorouracil (5-FU) is a well-established anticancer drug. Several studies have also demonstrated the anticancer potential of Cannabidiol (CBD) against various malignancies, including skin cancer. Reported synergistic effects of this combination fascinate researchers to consider this for the management of skin cancer. Methods: A simple and robust HPLC method for simultaneous estimation of 5-FU and CBD at its single wavelength (237 nm) was developed and validated. The separation of these compounds was performed on Waters (R) HPLC system with Hypersil (TM) C18 RP-column using methanol and water in gradient flow as mobile phase. The method could effectively quantify the nanogram levels of both analytes simultaneously in plasma spiked samples and various nanoformulations. The analytical performance of the proposed method was validated in terms of various parameters, such as linearity, ruggedness, specificity, and few others. Results: 5-FU as well as CBD were successfully detected at 237 nm with retention time of 1.4 and 1.84 minutes, respectively. Calibration curves were found to be linear with R-2 values of 0.985 and 0.984 for 5-FU and CBD, respectively. The method was linear, precise, specific and robust. Additionally, prepared method successfully determined concentration of both drugs in combitorial nanoformulations. Conclusion: The findings show that the developed method is simple, reliable, sensitive and economical. It could be employed for the simultaneous estimation of 5-FU and CBD in various in vitro and in vivo studies.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据