4.7 Article

Reconstruction for plane-wave ultrasound imaging using modified U-Net-based beamformer

期刊

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.compmedimag.2022.102073

关键词

Plane-wave ultrasound imaging; Beamforming; Deep learning; Reconstruction; Delay-and-sum; Coherent plane-wave compounding

资金

  1. Basic Science Research Program through the National Research Foundation of Korea (NRF) - Ministry of Science and ICT [NRF-2020R1A2C1011889]
  2. Ewha Womans University Research Grant of 2021

向作者/读者索取更多资源

This paper proposes a deep learning-based ultrasound image reconstruction method that can achieve high-resolution and high-frame-rate imaging. The proposed deep learning beamformer outperforms traditional methods in terms of image quality and frame rate.
An image reconstruction method that can simultaneously provide high image quality and frame rate is necessary for diagnosis on cardiovascular imaging but is challenging for plane-wave ultrasound imaging. To overcome this challenge, an end-to-end ultrasound image reconstruction method is proposed for reconstructing a high -resolution B-mode image from radio frequency (RF) data. A modified U-Net architecture that adopts EfficientNet-B5 and U-Net as the encoder and decoder parts, respectively, is proposed as a deep learning beamformer. The training data comprise pairs of pre-beamformed RF data generated from random scatterers with random amplitudes and corresponding high-resolution target data generated from coherent plane-wave compounding (CPWC). To evaluate the performance of the proposed beamforming model, simulation and experimental data are used for various beamformers, such as delay-and-sum (DAS), CPWC, and other deep learning beamformers, including U-Net and EfficientNet-B0. Compared with single plane-wave imaging with DAS, the proposed beamforming model reduces the lateral full width at half maximum by 35% for simulation and 29.6% for experimental data and improves the contrast-to-noise ratio and peak signal-to-noise ratio, respectively, by 6.3 and 9.97 dB for simulation, 2.38 and 3.01 dB for experimental data, and 3.18 and 1.03 dB for in vivo data. Furthermore, the computational complexity of the proposed beamforming model is four times less than that of the U-Net beamformer. The study results demonstrate that the proposed ultrasound image reconstruction method employing a deep learning beamformer, trained by the RF data from scatterers, can reconstruct a high-resolution image with a high frame rate for single plane-wave ultrasound imaging.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据