4.7 Article

Failure analysis of composite F-joint structures under tensile loading: Experimental and numerical study

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.compositesa.2022.106909

关键词

  Polymer-matrix composites (PMCs); Strength; Finite element analysis (FEA); Mechanical testing

资金

  1. National Key R&D Program of China [2021YFF0501800]
  2. National Natural SciencFoundation of China [52005256]
  3. Natural Science Foundation of Jiangsu Province [BK20190394]
  4. Jiangsu Postdoctoral Research Funding Program [2020Z437]
  5. Priority Academic Program Development of Jiangsu Higher Education Institutions

向作者/读者索取更多资源

This study analyzed the failure process of two different types of composite frame joints and found that the strength of joints reinforced with high-lock bolts and adhesive showed a significant improvement.
This paper presents an investigation on the failure process of two different types of composite frame joints (Fjoints), one is connected by high-lock bolts (FH) and the other reinforced by high-lock bolts and adhesive (FHA). The mechanical behavior of F-joints subjected to out-of-plane tension load is analyzed by experiment and numerical simulation. Test results show significant differences in the damage process, failure modes and strain distribution between FH and FHA. The strength of FHA increases nearly 13% compared to FH. Three-dimensional finite element models considering failure criterion and damage evolution are developed and implemented in the commercial code Abaqus/Standard through a user-defined subroutine UMAT. Cohesive zone model is used to simulate the adhesive layer damage of FHA. Simulating failure load and the damage process match the experimental data. The information on the failure mechanism and final failure load of composite F-joints is useful for the optimal design of such joints.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据