4.7 Article

Effect of airflow pattern and distance on removal of particulate matters and volatile organic compounds from cigarette smoke using Sansevieria trifasciata botanical biofilter

期刊

CHEMOSPHERE
卷 295, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.chemosphere.2022.133919

关键词

Botanical biofilter; Acetone; Formaldehyde; Particulate matters (PMs); Sansevieria trifasciata; Volatile organic compounds (VOCs)

资金

  1. Thailand Science Research and Innovation (TSRI) Basic Research Fund: Fiscal year 2021 [64A306000033]
  2. King Mongkut's University of Technology Thonburi (KMUTT) [1281/2019]

向作者/读者索取更多资源

This study examines the removal efficiency of particulate matters (PMs) and volatile organic compounds (VOCs) using a botanical biofilter. Results show that the removal efficiency depends on the distance and airflow pattern. The highest elimination of PMs is at 240 cm and 315 cm, while VOCs removal is high at 100 cm.
Botanical biofilters can effectively remove indoor air pollution. However, to apply botanical biofilters in situ, the distance of botanical biofilter to the pollutants and airflow pattern can be important factors impacting efficiency. This study examined the removal efficiency of particulate matters (PMs) and volatile organic compounds (VOCs) from cigarette smoke, such as formaldehyde and acetone, at various distances (100 cm, 175 cm, 240 cm, and 315 cm) using a Sansevieria trifasciata botanical biofilter. The botanical biofilter was placed inside a testing room (24 m3) and exposed to cigarette smoke. The pollutants removal efficiency was evaluated for six cycles (24 h/cycle) and one cycle as a recovery period where botanical biofilter was placed under normal conditions for 30 days. Results showed that the botanical biofilter could remove 140-250 mu g mxe213; 3, 147-257 mu g mxe213; 3, 212-455 mu g mxe213; 3 for PM1, PM2.5, and PM10, respectively, at 8 h. Total VOCs, formaldehyde, and acetone removal were 40%-65%, 46%-69%, and 31%-61% at 24 h. PMs and VOCs removal efficiency can be affected by both distance and pattern of airflow in the testing room. The highest PM1 and PM2.5 elimination appeared at 240 cm and 315 cm, while VOCs removal was high at 100 cm. Botanical biofilter creates airflow vortices around 100 cm, indicating low removal of PMs. This is the first study that demonstrated the effect of airflow patterns on different pollutants removal efficiency.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据