This article introduces a new multi-collector noble gas spectrometer, the Isotopx NGX-600, optimized for 40Ar/39Ar measurements. The performance of the NGX-600 is evaluated and compared with other noble gas spectrometers through analysis of atmospheric argon. The study provides optimal measurement parameters, correction methods, and comparative analysis of volcanic rock samples.
40Ar/39Ar geochronology relies on magnetic sector mass spectrometers to determine relative isotopic abundances. Ongoing technological developments within noble gas mass spectrometers over the last decade have led to analysis of increasingly smaller samples and higher precision, but also result in more complex data correction and interpretation. We describe a new multi-collector noble gas spectrometer, the Isotopx NGX-600, that is configured to optimize 40Ar/39Ar measurements. The NGX-600 is equipped with 9 Faraday collectors and one ion counting electron multiplier. Each Faraday is equipped with Isotopx ATONA (R) amplifier technology, enabling measurements spanning a dynamic range of amplified beam current from below 10(-16) A to above 10(-9) A. The performance of the NGX-600 is evaluated using both a conventional Nier-type ion source, and a next generation low temperature ion source, which allows for trap current variation from 200 mu A to 1000 mu A. We have performed over 3000 analyses of atmospheric argon to: (1) assess optimal measurement and integration times for blanks, baselines, and air aliquots of various ion intensities, (2) quantify the sensitivity via measurements of first principles 40Ar/39Ar standards, (3) compare the sensitivity between the conventional and new low temperature Nier-type ion sources, and (4) evaluate corrections associated with inter-Faraday biases, instrumental mass bias, and Faraday-multiplier gain. In addition to optimization experiments, we report a comparative analysis of both single crystal fusion and incremental heating data from Quaternary volcanic rocks obtained using both the 5-collector Nu Instruments Noblesse and the NGX-600 spectrometers.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据