4.5 Article

The Kocher-Langenbeck approach combined with robot-aided percutaneous anterior column screw fixation for transverse-oriented acetabular fractures: a retrospective study

期刊

BMC MUSCULOSKELETAL DISORDERS
卷 23, 期 1, 页码 -

出版社

BMC
DOI: 10.1186/s12891-022-05313-w

关键词

Robotics; Percutaneous screw; Minimally invasive surgical procedures; Acetabulum; Fracture Fixation; internal

向作者/读者索取更多资源

This study compared the therapeutic effects of robot-aided percutaneous anterior column screw fixation versus minimally invasive anterior plate fixation for transverse-oriented acetabular fractures (TOAFs). The results showed that robot-aided screw fixation had obvious advantages in surgical time, blood loss, and invasiveness. The combination of the Kocher-Langenbeck approach with minimally invasive anterior plate fixation was also a reliable alternative for TOAFs, with similar reduction quality and functional results.
Objective Transverse-oriented acetabular fractures (TOAFs), including transverse, transverse with posterior wall and T-shaped fractures, are always challenging for double-column reduction and fixation with minimally invasive method. The purpose of this study is to compare the therapeutic effects of robot-aided percutaneous anterior column screw fixation versus minimally invasive anterior plate fixation for TOAFs based on the Kocher-Langenbeck (K-L) approach. Methods Patients suffering TOAFs that were fixed by robot-aided percutaneous anterior column screw fixation or minimally invasive anterior plate fixation associated with posterior fixation via the K-L approach were divided into two groups: group A (screw fixation) and group B (plate fixation). Surgical time, blood loss, incision length for anterior fixation and complications were recorded. Fracture reduction quality was evaluated using criteria described by Matta. Fracture healing was assessed on the series of pelvic radiographs at each follow-up. Functional outcomes were investigated using the modified Postel Merle D'Aubigne score at the final follow-up. Results Twenty-nine patients with TOAFs, including 12 patients in group A and 17 patients in group B, were evaluated for study eligibility. The mean surgical time of anterior fracture fixation was 18.7 +/- 4.6 min in group A and 33.4 +/- 5.0 min in group B (P < 0.001). The amount of intraoperative blood loss was 615.6 +/- 178.7 ml in group A and 719.3 +/- 199.0 ml in group B (P < 0.001). Incision length for anterior fixation was 9.0 +/- 1.8 mm in group A and 81.2 +/- 7.3 mm in group B (P < 0.001). The complications related to the surgery of anterior column only occurred in group B (lateral femoral cutaneous nerve palsy in 1 patient and groin discomfort in 1 patient). No significant differences in reduction quality, hospital stay, fracture healing time and functional results were noted between the two groups. Conclusion The K-L approach combined with robot-aided anterior column screw fixation is a safe and effective option for TOAFs. Compared with minimally invasive anterior plate fixation, robot-aided screw fixation has obvious advantages on surgical time, blood loss, and invasiveness. The K-L approach combined with minimally invasive anterior plate fixation can also be a reliable alternative for TOAFs, with the similar reduction quality and functional results.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据