4.3 Article

A Comparison of the Commonly Used Surrogate Markers for Citrate Accumulation and Toxicity during Continuous Renal Replacement Therapy with Regional Citrate Anticoagulation

期刊

BLOOD PURIFICATION
卷 51, 期 12, 页码 997-1005

出版社

KARGER
DOI: 10.1159/000524129

关键词

Continuous renal replacement therapy; Regional citrate anticoagulation; Total-to-ionized calcium ratio; Citrate toxicity

资金

  1. Sunshine Coast University Hospital Foundation

向作者/读者索取更多资源

This study compared surrogate markers for assessing citrate accumulation or toxicity and found that the uncorrected total-to-ionized calcium ratio is superior to other markers. However, this method is still not an ideal way of assessing citrate accumulation or toxicity.
Introduction: Continuous renal replacement therapy using regional citrate anticoagulation is commonly used as a modality of organ support in the critically ill population. Currently, citrate accumulation or toxicity is assessed using surrogate markers, notably the uncorrected total-to-ionized calcium ration. The accuracy and utility of this method have been questioned. Objectives/Aims: The aim of this study was to compare the surrogate markers used for assessing citrate accumulation or toxicity using the measurement of plasma citrate as the gold standard. Methods: Blood was sampled from 20 patients before, during, and after episodes of filtration with citrate concentration measured using spectrophotometry. Demographic and other clinical and biochemical data were also collected. According to protocol, a 15 mmol/L solution of trisodium citrate was used as the prefilter anticoagulant. Results were analyzed using STATA (v16.0) and presented as mean (SD), median (IQR), or simple proportion. Univariate linear regression using citrate concentration as the dependent variable was performed with all surrogate markers. Results: Twenty patients (17 males) were enrolled in the study with a mean (SD) age of 62.7 (9.9) years. The uncorrected calcium ratio had the best fit to the citrate data with an R-2 value of 0.39. The albumin-corrected calcium ratio, pH, anion gap (AG), albumin-corrected AG, standard base excess, and strong ion gap all had R-2 values less than 0.05. Conclusion(s): In the absence of direct measurement of citrate concentration, uncorrected total-to-ionized calcium ratio is superior to other surrogate markers, though not ideal, in assessing citrate accumulation or toxicity.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据