4.6 Article

Cross-sectional diagnostic accuracy study of self-testing for proteinuria during hypertensive pregnancies: The UDIP study

期刊

出版社

WILEY
DOI: 10.1111/1471-0528.17180

关键词

diagnostic accuracy study; hypertension; pre-eclampsia; pregnancy; proteinuria; self-testing

资金

  1. National Institute for Health Research (NIHR) [RP-PG-0614-20 005, NIHR-RP-R2-12-015]
  2. National Institute for Health Research (NIHR) Collaboration for Leadership in Applied Health Research (CLAHRC)
  3. Primary Care Research Trust
  4. Health Foundation
  5. NIHR Oxford Biomedical Research Centre

向作者/读者索取更多资源

The study aimed to determine the accuracy of self-testing for proteinuria during pregnancy. The results showed that pregnant women can visually read a dipstick for urinary protein with similar accuracy to antenatal healthcare professionals. Self-testing has the potential to be part of self-monitoring during pregnancy.
Objective To determine the accuracy of self-testing for proteinuria during pregnancy. Design Diagnostic accuracy study. Setting Antenatal clinics, maternity assessment units and inpatient wards at three hospital sites. Population or Sample 345 pregnant women. Methods Pregnant women self-tested in-clinic for urinary protein using visually read dipsticks with samples then sent for laboratory estimation of the spot protein-creatinine ratio (PCR) (primary reference test). Secondary index tests included testing by antenatal healthcare professionals and an automated colorimetric reader. Main outcome measures Sensitivity, specificity, negative predictive value, positive predictive value and likelihood ratios were calculated for self-testing (primary index test) along with healthcare professional and colorimetric testing compared to the primary reference test (PCR). Results 335/345 (97%) had sufficient data to be included in the analysis. Self-testing had a sensitivity of 0.71 (95% confidence interval [CI] 0.62-0.79) and a specificity of 0.89 (95% CI 0.84-0.92) compared to PCR. Sensitivity and specificity of testing by healthcare professionals and the colorimetric reader were similar: sensitivity 0.73 (95% CI 0.64-0.80) and 0.78 (95% CI 0.69-0.85), respectively; specificity 0.88 (95% CI 0.82-0.92) and 0.83 (95% CI 0.78-0.88), respectively. Conclusion Pregnant women can visually read a dipstick for urinary protein with similar accuracy to antenatal healthcare professionals. Automated colorimetric testing was not significantly different, in contrast to some previous studies. Self-testing has the potential to form part of a self-monitoring regime in pregnancy.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据