4.8 Article

A pretreatment-free electrical capacitance biosensor for exosome detection in undiluted serum

期刊

BIOSENSORS & BIOELECTRONICS
卷 199, 期 -, 页码 -

出版社

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2021.113872

关键词

Exosome sensing; Capacitance sensor; Interdigitated micro-gap electrode; Aptamer; CD63 protein

资金

  1. National Research Foundation of Korea (NRF) - Korea government (MSIT) [2021R1C1C1005583]
  2. Industrial Core Technology Development Program - Ministry of Trade, Industry and Energy (MOTIE, Korea) [20009121]
  3. Ministry of Trade, Industry and Energy (MOTIE, Korea) [20000580]
  4. Chungnam National University
  5. Korea Evaluation Institute of Industrial Technology (KEIT) [20009121, 20000580] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)
  6. National Research Foundation of Korea [2021R1C1C1005583] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

向作者/读者索取更多资源

In this study, a capacitance-based electrical biosensor was developed to detect exosomes in undiluted serum samples without pretreatment. The biosensor utilized a DNA aptamer for CD63 protein detection and MoS2 nanoparticles to enhance the electrical sensitivity. The interdigitated micro-gap electrode system efficiently amplified the electrical signal for exosome detection, offering high selectivity and sensitivity. The biosensor exhibited linearity between the capacitance signal and exosome concentration in serum, with a detection limit of 2192.6 exosomes/mL.
The exosome is considered a useful biomarker for the early diagnosis of cancer. However, pretreatment of samples used in diagnosis is time-consuming. Herein, we fabricated a capacitance-based electrical biosensor that requires no pretreatment of the sample; it is composed of a DNA aptamer/molybdenum disulfide (MoS2) heterolayer on an interdigitated micro-gap electrode (IDMGE)/printed circuit board (PCB) system for detecting exosomes in an undiluted serum sample. The DNA aptamer detects the CD63 protein on the exosome as the biomarker, while the MoS2 nanoparticle enhances electrical sensitivity. In this study, for the first time, the IDMGE system was used to amplify the electrical signal efficiently for exosome detection. The IDMGE amplifies the capacitance signal as the gap between electrodes decreases, making it easy to detect the target by utilizing the heightened sensitivity. Moreover, it is possible to immobilize a bio-probe more efficiently than with an electrical sensitivity-enhancing electrode with the same area. The thiol-modified (SH-) CD63 DNA aptamer was introduced as the bio-probe that selectively binds to the CD63 protein on the exosome surface. The capacitance signal from the IDMGE electrical sensor increased linearly with the increase in the concentration of exosomes in human serum expressed on a logarithmic scale, the detection limit being 2192.6 exosomes/mL. The proposed biosensor can detect exosomes in undiluted human serum with high selectivity and sensitivity. A blind test was also carried out to test the reliability of the biosensor. The capacitance-based electrical biosensor thus offers a new platform for cancer diagnosis in the future.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据