4.6 Article

MLP-BP: A novel framework for cuffless blood pressure measurement with PPG and ECG signals based on MLP-Mixer neural networks

期刊

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.bspc.2021.103404

关键词

Cuffless blood pressure; Blood pressure estimation; MLP-Mixer neural network; PPG and ECG; Deep learning; Signal filtering

资金

  1. National Natural Science Foundation of China [61620106012, 61773042]
  2. Beijing Natural Science Foundation [4202042]
  3. Key Research and Development Program of Zhejiang Province, China [2020C01109, 2021C03050]
  4. Macao Science and Technology Development Fund [0022/2019/AKP]

向作者/读者索取更多资源

This study proposed a novel deep neural network MLP-BP for estimating blood pressure from PPG and ECG signals. By preprocessing ECG and PPG signals using MFMC and integrating them into multi-channel data, and estimating with MLP-Mixer, competitive results were achieved.
High blood pressure (BP) is a major source of death worldwide as it slows down the flow of blood and oxygen, and leads to various chronic diseases such as chest pain (angina), heart disease and heart failure. Therefore, regular measurement and monitoring of BP is an essential element of the home healthy settings, especially for the elderly. In this study, a novel deep neural network (called MLP-BP, which including gMLP-BP and MLPlstm-BP) adapted from MLP-Mixer is proposed to estimate BP from plethysmography (PPG) and electrocardiograph (ECG) signal. More precisely, a novel multi-filter to multi-channel (MFMC) is presented for preprocessing ECG and PPG signals, namely using various filters and filtering parameters to handle with ECG and PPG, and integrating the filtered bio-signals into multi-channel data. Then, the multi-channel data is fed into the proposed methods to estimate blood pressure directly. The up-to-date concept MLP-Mixer is employed in the proposed frameworks, which are both end-to-end pipelines without any handcrafted feature extraction operation. MLPlstm-BP (gMLPBP) achieves the predicted diastolic BP with a mean absolute error (MAE) of 2.13 (2.47) mmHg, and with a standard deviation (SD) of 3.07 (3.52) mmHg; those of systolic BP is an MAE of 3.52 (4.18) mmHg, and a SD of 5.10 (5.87) mmHg on the MIMIC II dataset. In addition, the testing results are all meet the highest level of the Association for the Advancement of Medical Instrumentation (AAMI) and British Hypertension Society (BHS). Extensive experiments demonstrate that the proposed methods attain competitive results over state-of-the-art (SOTA) learning-based pipelines.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据