Experimental study on temperature uniformity and heat transfer performance of nitrogen loop heat pipe with large area and multi-heat source

期刊

APPLIED THERMAL ENGINEERING
卷 210, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2022.118344

关键词

Large area loop heat pipe; Multiple heat source; Cryogenic; Thermal characteristics

资金

  1. Super Power and Cryogenic Thermal Management Technology project
  2. Second Youth Peak program of Beijing Institute of Spacecraft System Engineering and Science Foundation for Distinguished Young Scholars [2020-JCJQ-ZQ-042]

向作者/读者索取更多资源

With the development of space technology, the thermal control requirements for spacecraft are increasing. In this study, a large-area cryogenic loop heat pipe is designed for an optical telescope, which provides efficient and reliable heat dissipation with an average temperature performance of less than 5K.
With the development of space technology, the requirements of thermal control on spacecraft are increasing. In space missions, due to the improvement of the detection accuracy, the diameter of deep space telescope is becoming larger and larger. These detection instruments need efficient and reliable thermal management. Thus, the application of the large-scale cryogenic cooling technology, which can provide heat dissipation for the continuous and long life of the detector, has become a difficult problem. In the present study, a large-area cryogenic loop heat pipe is designed for the optical telescope. It is a good combination of multi heat source and large-area cryogenic loop heat pipe. The main evaporator is cylindrical due to fit the lens barrel. The heat exchange area can reach 1 m(2), and the average temperature performance is less than 5 K. The condenser adopts the form of parallel pipeline to further reduce the system resistance and ensure the smooth operation of loop heat pipe. Its operation stability and temperature uniformity of the main evaporator under different total loads are experimentally studied and analyzed. It is proved that the loop heat pipe is feasible for large area multi-heat source cryogenic loop heat pipe in engineering. It can also start up and run normally under anti-gravity conditions. The experimental results show that the large area multi-source heat collection cryogenic loop heat pipe can be started and run normally in the temperature range of 80-120 K.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据