4.7 Article

A parametric study on the performance of vapor chamber in association with pillar distribution

期刊

APPLIED THERMAL ENGINEERING
卷 207, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2022.118217

关键词

Vapor chamber; Pillar distribution; Thermal resistance; Copper screen mesh; Electronic cooling

资金

  1. M/s Cooler Master
  2. Ministry of Science and Technology, Taiwan [108-2221-E-009-058-MY3]

向作者/读者索取更多资源

This study investigates the influence of pillar distribution on the performance of a vapor chamber. Through the fabrication and testing of 11 different models, it is found that pillar distribution can affect the thermal resistance and maximum heating load of the vapor chamber. The experimental results show that merely increasing the number of pillars does not always reduce the thermal resistance; a better pillar distribution can improve vapor flow and enhance the performance of the vapor chamber.
The performance of vapor chamber is significantly affected by the wick structure, height of the vapor cavity, pillar structure, working fluid, filling ratio, and heat source area. Besides, it can also be influenced by the pillar distribution, which has not been extensively studied in prior literature. Therefore, the present study investigates the influence of pillar distribution on the vapor chamber performance. Totally 11 different vapor chamber models are fabricated and tested, and water is selected as a working fluid for all the samples. The examined geometric features include different mesh layers, mesh sizes, wick structure in condenser surface, pillar distributions, and vapor core space. The results showed that the evaporator with a single-layered mesh provided the thermal resistance of 0.19 K W-1, while triple-layered mesh yielded a thermal resistance of 0.24 K W-1. Moreover, the 2 x 200 mesh offered a maximum heating load of 161 W with a thermal resistance of 0.18 K W-1 against the maximum heating load of 120 W and 75.6 W by the 2 x 150 and 2 x 100 mesh, respectively. The experimental results showed that increasing the pillar numbers alone may not always reduce the thermal resistance, a better pillar distribution can help to direct the vapor flow and improve the performance of the vapor chamber. The proposed vapor chamber with a novel X-wing patterned pillar distribution can offer a thermal resistance of 0.19 K W-1 at a heating load of 146.6 W.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据