4.8 Article

Simultaneous Detection of CO and NH3 Gases at Room Temperature with an Array of ZnS Chemiresistive Sensors and the Superposition Principle

期刊

ANALYTICAL CHEMISTRY
卷 94, 期 11, 页码 4602-4609

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acs.analchem.1c04319

关键词

-

资金

  1. Ministry of Education (MOE), India

向作者/读者索取更多资源

Simultaneous detection of multiple toxic gases using room temperature gas sensors is important in low-power environmental monitoring. This study proposes a computationally less intensive method to predict the composition of mixed gases using linear gas sensors. The proposed algorithm can accurately predict the concentrations of individual gases in mixed gas with low energy consumption.
Simultaneous detection of multiple toxic gases in the air using room temperature gas sensors is significant in low-power environmental monitoring applications. However, the low-temperature resistive gas sensors are sensitive to more than one gas, and thus, an array of gas sensors and high energy-consuming machine learning algorithms are required to predict the concentrations of the individual gases in mixed target gas. Here, we report a computationally less intensive method to predict the composition of the target gases using linear gas sensors. A sensor array consisting of two ZnS resistive gas sensors biased at different voltages in conjunction with the superposition principle is used to predict the concentration of individual gases in the binary mixture of NH3 and CO present in the air. Further, the effect of humidity on response is mitigated by formulating the sensitivity of the sensors as a function of relative humidity. The proposed algorithm predicted the concentration of the individual gases in mixed gas with a maximum absolute error of similar to 15% irrespective of humidity levels, which is practically allowed in most gas sensing applications. As the superposition principle is a low-power consuming technique, the proposed approach can be used in applications where trace levels of gases in mixed targets need to be detected with energy-efficient methods.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据