4.4 Article

FULL-SCALE AIR EMISSIONS MONITORING AND CASTING QUALITY DEMONSTRATION OF A HYBRID HYDROLYZED COLLAGEN-ALKALI SILICATE CORE BINDER

期刊

INTERNATIONAL JOURNAL OF METALCASTING
卷 10, 期 2, 页码 172-189

出版社

SPRINGER INTERNATIONAL PUBLISHING AG
DOI: 10.1007/s40962-016-0021-y

关键词

core binders; collagen; silicates; phenolic urethane; air emissions; volatile organic compounds; metal casting; stack test

资金

  1. Ben Franklin Technology
  2. National Science Foundation [1338710]
  3. Furness-Newburge, Inc.
  4. Div Of Industrial Innovation & Partnersh
  5. Directorate For Engineering [1338710] Funding Source: National Science Foundation

向作者/读者索取更多资源

When comparing a novel collagen and alkali silicate core binder system to a conventional phenolic urethane binder system during full-scale trials, the phenolic urethane incurred a 33.3 % higher emissions rate than did the novel binder system. This was chronicled during several hours of stack tests in a full-scale trial demonstration of 3500 novel cores at a high-volume automotive ductile iron foundry. Baseline phenolic urethane emissions were determined immediately prior to running the collagen and alkali silicate cores, when making an identical casting. Approximately 10 % of the demonstration iron castings were inspected for defects, of which none (0 %) were scrapped on account of core-related defects. Also, the novel core's shakeout was complete. These favorable results were achieved with humidity-free storage of the cores over the 10 days that the cores were made. These novel demonstration cores required somewhat longer curing time in the core-making machine, than did conventional phenolic urethane cores; and this curing rate was influenced by air flow and pressure into the core box. Also, tensile specimen tests of the collagen and alkali silicate-adhered system were higher than that of the conventional phenolic urethane system. When exposed to high humidity levels (80-95 % relative humidity) for prolonged periods of time (10 days), the collagen and alkali silicate-adhered tensile specimens degraded in terms of tensile strength and scratch hardness. These losses mostly rebounded when the tensile specimens were re-dried.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据