4.5 Article

Intrauterine contraceptive device rupture. Follow-up of a retrospective cohort and clinical protocol. RUDIUS study

期刊

HELIYON
卷 8, 期 1, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.heliyon.2022.e08751

关键词

Intrauterine dispositive; Fractured IUD; IUD breakage; Cohort study; Clinical protocol

向作者/读者索取更多资源

This study investigated factors influencing intrauterine fragment retention after device rupture. The main factors positively influencing complete expulsion of the fragmented IUD were elapsed time of 45 days or more, intercurrent menstruation or spontaneous fracture. It is recommended to observe for at least 1.5 months after fracture, allowing at least one intercurrent period to elapse prior to any therapeutic intervention.
Objective: Intrauterine device fracture, as we know it today, is an infrequent event, usually described as isolated cases. The purpose of this study was to look for factors influencing intrauterine fragment retention after device rupture. Study design: Retrospective cohort study. A total of 135 patients were recruited, and the cohort follow-up ran for three full years from 2018 to 2020. Results: Thirty-three percent of patients had a retained intrauterine fragment compared to 82 of 123 (66.7%) who had expelled it spontaneously. In the group of patients who had at least one intercurrent period between device fracture and confirmatory fragment persistent test, we found persistence of intrauterine fragment in 18 of 71 (25.4%) patients compared to 53 of 71 (74.6%) who did not (p = 0.047). A total of 6 of 39 (15.4%) of the patients with spontaneous rupture of the device presented with persistence of the intrauterine fragment compared to 32 of 81 (39.2%) of the group with fracture after manipulation (p = 0.006). The mean time elapsed from the fracture to the confirmatory test in the patients who had persistence of the fragment was 26.97 days (range from 0 to 116), while in those who expelled it spontaneously, a mean of 45.59 days (range 7-267) had elapsed (p = 0.003). Conclusions: The main factors positively influencing complete expulsion of the fragmented IUD were elapsed time of 45 days or more, intercurrent menstruation or spontaneous fracture. Therefore, the proposed protocol calls for expectant management for at least 1.5 months after fracture, allowing at least one intercurrent period to elapse prior to any therapeutic manoeuvre.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据