4.7 Article

Dual-Shaped Silver Nanoparticle Labels for Electrochemical Detection of Bioassays

期刊

ACS APPLIED NANO MATERIALS
卷 4, 期 10, 页码 10764-10770

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acsanm.1c02207

关键词

spherical silver nanoparticles; silver nanocubes; metalloimmunoassay; galvanic exchange; N-terminal prohormone brain natriuretic peptide; heart failure

资金

  1. National Heart, Lung, and Blood Institute of the National Institutes of Health [R01HL137601]
  2. Robert A. Welch Foundation [F-0032]

向作者/读者索取更多资源

This paper demonstrates the use of dual-shaped silver nanoparticles as detection labels for electrochemical bioassays, showing that using both shapes simultaneously can lower the limit of detection compared to using either shape independently. By optimizing the ratio of the two types of AgNP labels, it is possible to decrease the LOD of the assays without compromising the dynamic range, achieving the clinically relevant range for heart failure risk stratification.
In this paper, we demonstrate the use of dual-shaped silver nanoparticles (AgNPs) as detection labels for electrochemical bioassays. The key finding is that by simultaneously using AgNP labels having two different shapes, the limit of detection (LOD) for the assays is lowered compared to using either of the two shapes separately. The two shapes were silver nanocubes (AgNCs) having edge lengths of 40 +/- 4 nm and spherical AgNPs (sAgNPs) having diameters of 20 +/- 3 nm. Two different bioassays were examined. In both cases, the Ag labels were functionalized with antibodies. In the first assay, the labels are directly linked to a second antibody immobilized on magnetic beads. In the second assay, the antibodies on the AgNP labels and the antibodies on the magnetic beads are linked via a peptide. The peptide is N-terminal prohormone brain natriuretic peptide (NT-proBNP), which is a heart-failure marker. The efficacy of the two electrochemical assays as a function of the ratio of the two labels was investigated using a galvanic exchange/anodic stripping voltammetry method. The key finding is that by optimizing the ratio of the two types of AgNP labels, it is possible to decrease the LOD of the assays without compromising the dynamic range compared to using either of the two labels independently. This made it possible to achieve the clinically relevant range for NT-proBNP analysis used by physicians for heart failure risk stratification.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据